The Animation Wheel movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a motor failure (defective motor or a defective
motor IC drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
The Dimmer movement is not located in the default position after the
reset. This message will appear after a fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a motor failure (defective motor or defective motor IC drive on
main PCB). This error may also be displayed if the head was blocked
during a reset function.
The Frost Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Fan Moving Wheel is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Array Lens Wheel is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
Error information from JB1 port on 1U01 PCB.
Error information from JB2 port on 1U01 PCB.
Error information from JB1 port on 3U PCB.
Error information from JB2 port on 3U PCB.
Error information from JB2 port on 4U PCB.
Error information from JB1 port on 5U PCB.
Error information from JB1 port on 6U PCB.
Error information from JB1 port on 7U PCB.
Error information from JB2 port on 7U PCB.