Elation PROTEUS HYBRID WMG User Manual
Hide thumbs Also See for PROTEUS HYBRID WMG:

Advertisement

PROTEUS HYBRID &
PROTEUS HYBRID WMG
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROTEUS HYBRID WMG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elation PROTEUS HYBRID WMG

  • Page 1 PROTEUS HYBRID & PROTEUS HYBRID WMG User Manual...
  • Page 2 Elation Professional B.V . | Junostraat 2 | 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 (728) 282-7070 DOCUMENT VERSION Due to additional product features and/or enhancements, an updated version of this document may be available online.
  • Page 3: Table Of Contents

    CONTENTS GENERAL INFORMATION IP65 RATED LIMITED WARRANTY (USA ONLY) SAFETY GUIDELINES DISCHARGE LAMP WARNING OVERVIEW LAMP INSTALLATION GOBO INSTALLATION FIXTURE INSTALLATION REMOTE DEVICE MANAGEMENT (RDM) SYSTEM MENU E-FLY WIRELESS DMX SET UP DMX CHANNEL FUNCTIONS AND VALUES ERROR CODES MAINTENANCE SPECIFICATIONS COLORS AND GOBOS | ANIMATION WHEEL DIMENSIONAL DRAWINGS...
  • Page 4: General Information

    IP65 Rated RJ45 Cable (Fixture to Fixture Interconnect Use Only!) IP65 Power Cable CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments, or suggestions. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST support@elationlighting.com...
  • Page 5: Ip65 Rated

    IP65 RATED The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
  • Page 6: Limited Warranty (Usa Only)

    1. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase.
  • Page 7: Safety Guidelines

    To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation.
  • Page 8 SAFETY GUIDELINES RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV COLOR FILTER. WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE TO UV COLOR FILTER.
  • Page 9: Discharge Lamp Warning

    DISCHARGE LAMP WARNING This fixture is fitted with a DISCHARGE LAMP, which is highly susceptible to damage if improperly handled. NEVER touch the lamp with your bare hands, as the oil from your hands will shorten the life of the lamp. Also, NEVER move the fixture until the lamp has had ample time to cool.
  • Page 10: Overview

    OVERVIEW 1. Lens 2. E-FLY Wireless DMX Indicator LED 3. LCD Menu Control Display 4. MODE/ESC Button 5. LEFT Button 6. DOWN Button 7. ENTER Button 8. RIGHT Button 9. UP Button 10. Power IN 11. Fuse 12. RJ45 Ethernet IN 13.
  • Page 11: Lamp Installation

    LAMP INSTALLATION LAMP REPLACEMENT Please note that due to the nature of the Philips™ Platinum 21R Lamp and the optical path of the fixture, the lamp MUST BE replaced at 1,500 hours. Use only Genuine Original Philips™ Platinum 21R Lamps. Other brand lamps may cause damage and void warranty! INSTALLING OR REPLACING THE LAMP To ensure a proper/safe lamp change, carefully read all the following instructions.
  • Page 12 LAMP INSTALLATION WARNING! LAMP REPLACEMENT SHOULD ONLY BE DONE BE A TRAINED TECHNICIAN. 1. Turn OFF power and allow approximately 60 minutes for the fixture to cool down. TILT Lock Lock 2. Place head in a right-angle horizontal position and engage both the PAN and TILT locks for added stability while replacing the lamp.
  • Page 13 LAMP INSTALLATION 5. Remove (4x) 3mm hex-head screws holding 4. Unclip the rear cover safety cable. the center heatsink module. 6. Unclip the center heatsink module safety cable.
  • Page 14 LAMP INSTALLATION 7. Gently remove the (2x) spade terminals connected to the lamp. 8. Loosen the lamp retaining arm screw and the pull arm out. Then unclip the lamp retaining clip...
  • Page 15 LAMP INSTALLATION 9. Swing the lamp retaining clip out, then carefully remove the lamp. WARNING! LAMP MAY BE HOT. USE CAUTION WHEN TOUCHING LAMP WITH BARE HANDS. 10. Carefully install the new lamp then follow the removal instruction steps in reverse order. NOTE: Brush away any debris using a nonabrasive brush before replacing the heatsink.
  • Page 16 MODULE USING A NONABRASIVE BRUSH BEFORE INSTALLING! CAREFULLY INSPECT HEATSINK GASKET FOR SIGNS OF WEAR SUCH AS CRACKING OR HARDENING, DEFORMITIES, OR ALIGNMENT ISSUES BEFORE INSTALLING! ITEMS ABOVE CAN IMPEDE THE IP65 INTEGRITY AND/OR CAUSE INTERNAL DAMAGE. CONTACT ELATION SERVICE REGARDING GASKET REPLACEMENT IF NEEDED.
  • Page 17 LAMP INSTALLATION TORQUE SETTINGS FOR SCREWS HEATSINK MODULE SCREWS MUST BE TIGHTENED WITH A TORQUE WRENCH. The (4x) hex-head screws holding the heatsink module MUST be tightened with a torque- wrench (not included). TORQUE SETTING = 11 lbf-in. (12.7kgf-cm) * * lbf-in = Pound Force Inches | kgf-cm = Kilogram Force Centimeters CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
  • Page 18 IP TESTING TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST FIXTURE USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS. CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE’S LENS WHILE...
  • Page 19: Gobo Installation

    GOBO INSTALLATION WARNING! GOBO REPLACEMENT SHOULD ONLY BE DONE BE A TRAINED TECHNICIAN. 1. Turn OFF power and allow approximately 60 minutes for the fixture to cool down. TILT Lock PAN Lock 2. Place the head in an upright vertical position and engage both the PAN and TILT locks for added stability while replacing the gobo.
  • Page 20 GOBO INSTALLATION 4. Unclip the panel safety cable one side of the head. 5. Unclip the panel safety cable on the opposite side of the head.
  • Page 21 GOBO INSTALLATION 6. Cut the plastic cable-ties holding wires and disconnect connectors attached to the effect module.
  • Page 22 GOBO INSTALLATION 7. Remove (2x) #2 Philips screws securing effect 8. Gently lift GOBO lens away from effect module. module. 9. Carefully remove the effect module from 10. Place the effect module on firm clean surface fixture. and locate GOBO to replace. 11.
  • Page 23 GOBO INSTALLATION 12. Carefully remove retaining spring. CAUTION! DO NOT SCRATCH GOBO OR GOBO HOLDER! 13. Carefully separate the GOBO disc from the GOBO Holder. 14. Carefully remove the retaining ring washer attached to the GOBO. SAVE RETAINING RING WASHER FOR USE WITH THE NEW REPLACEMENT GOBO! RETAINING RING MUST BE USED IN ORDER TO PREVENT GOBO BURNING! 15.
  • Page 24 PANELS USING A NONABRASIVE BRUSH BEFORE INSTALLING! CAREFULLY INSPECT GASKETS FOR SIGNS OF WEAR SUCH AS CRACKING OR HARDENING, DEFORMITIES, OR ALIGNMENT ISSUES BEFORE INSTALLING! ITEMS ABOVE CAN IMPEDE THE IP65 INTEGRITY AND/OR CAUSE INTERNAL DAMAGE. CONTACT ELATION SERVICE REGARDING GASKET REPLACEMENT IF NEEDED.
  • Page 25 * lbf-in = Pound Force Inches | kgf-cm = Kilogram Force Centimeters CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A GOBO REPLACEMENT, TEST FIXTURE USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
  • Page 26 Extended testing of custom gobo designs is highly recommended prior to using. PLEASE CONTACT ELATION CUSTOMER SUPPORT FOR FURTHER INFORMATION...
  • Page 27 Full Color / Solid Area custom gobo designs are NOT RECOMMENDED due to the extreme high temperature optical system which can reach up to 842 F (450 ° ° Custom gobo designs as illustrated below can burn during extended use periods. PLEASE CONTACT ELATION CUSTOMER SUPPORT FOR FURTHER INFORMATION...
  • Page 28: Fixture Installation

    FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5.0 feet (1.5m) away from any flammable materials, decorations, pyrotechnics, etc. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 40 FEET (12 METERS) MAXIMUM TEMPERATURE OF EXTERNAL SURFACE 212°...
  • Page 29 FIXTURE INSTALLATION CLAMP INSTALLATION The fixture can be attached to a metal truss/structure using. When mounting this fixture to truss be sure to secure (2) appropriately rated clamps (not included) to the (2) Omega Brackets (included) Be sure to attach the Safety Cable (not included) to the fixture using the safety cable rigging point integrated into the bottom of the fixture.
  • Page 30 FIXTURE INSTALLATION OVERHEAD RIGGING Overhead rigging requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself.
  • Page 31 FIXTURE INSTALLATION CONNECTIONS ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUITE. TO MAINTAIN IP65 RATING INTEGRITY, AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.
  • Page 32 LEDs. This issue is not specific only to ELATION lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
  • Page 33: Remote Device Management (Rdm)

    REMOTE DEVICE MANAGEMENT (RDM) NOTE: For RDM to work properly, RDM enabled equipment must be used through-out the entire system, including DMX data splitters and wireless systems. Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for lighting, allowing the DMX systems of the fixtures to be modified and monitored remotely.
  • Page 34: System Menu

    MODE/ESC button for 10 seconds. The LCD Menu Control Display will shut OFF automatically about 60 seconds from the last button press. AN ELATION E-LOADER III CAN BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. TO ORDER THIS DEVICE, PLEASE CONTACT ELATION SUPPORT FOR FURTHER DETAILS.
  • Page 35 SYSTEM MENU Features are subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD ) Set Dmx Address A001~AXXX DMX Address Setting...
  • Page 36 SYSTEM MENU Features are subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD ) Address via DMX ON /OFF Address Via DMX...
  • Page 37 SYSTEM MENU Features are subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD ) Basic Mode Standard Mode Extended Mode...
  • Page 38 PERSONALITY - Status Settings - Address Via DMX When ON, define the desired DMX address via an external controller. NOTE: This process assumes the fixture DMX address is set to 001. If fixture DMX address is not at 001, you must adjust the channel numbers accordingly in order for this feature to work.
  • Page 39 ELATION E-FLY WIRELESS TRANSCEIVER only has 0-14 wireless channels, NO CH 15. 4. Set fixture DMX address in the Set Dmx Address sub menu of the FUNCTION main system menu.
  • Page 40: E-Fly Wireless Dmx Setup

    E-FLY WIRELESS DMX SETUP Wireless DMX signal can penetrate walls, glass, metal, and most objects. However, there are many factors that can affect and/or interrupt the wireless DMX signal, one of which is people. Therefore, it is highly recommended to position the wireless antenna a minimum of 9.8 ft. (3m) above audiences and/or above ground level.
  • Page 41: Dmx Channel Functions And Values

    DMX CHANNEL FUNCTIONS AND VALUES DMX Channel Values / Functions (26, 24, 37 DMX Channels) Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION...
  • Page 42 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 43 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 44 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 45 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 46 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 47 DMX CHANNEL FUNCTIONS AND VALUES Supports Software Versions: ≥ 1.8.0 Features subject to change without any prior written notice. *Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings. MODE / CHANNEL VALUE FUNCTION BASIC STAND...
  • Page 48: Error Codes

    IF A BALLAST ERROR MESSAGE APPEARS, TURN THE LAMP OFF FOR 3-5 MINUTES TO RESET THE BALLAST. IF AFTER 5-MINUTES A BALLAST ERROR STILL APPEARS, TURN THE FIXTURE OFF TO RESET THE BALLAST. IF A BALLAST MESSAGE STILL APPEARS, PLEASE CONSULT ELATION CUSTOMER SUPPORT.
  • Page 49 ERROR CODES Error Codes are subject to change without any prior written notice. ERROR CODES DESCRIPTION The PAN movement is not located in the default position after the reset. This message will appear after a fixture reset if the magnetic- PAN Er indexing circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive...
  • Page 50 ERROR CODES Error Codes are subject to change without any prior written notice. ERROR CODES DESCRIPTION The Rotating Gobo rotation movement is not located in the default position after the reset. This message will appear after a fixture Rotating Gobo reset if the gobo wheel’s magnetic-indexing circuit malfunctions Rotation Er (sensor failed or magnet is missing) or there is a stepper motor failure...
  • Page 51 ERROR CODES Error Codes are subject to change without any prior written notice. ERROR CODES DESCRIPTION The Animation Wheel movement is not located in the default position after the reset. This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions (sensor failed or magnet is Animation Wheel Er missing) or there is a motor failure (defective motor or a defective...
  • Page 52 ERROR CODES Error Codes are subject to change without any prior written notice. ERROR CODES DESCRIPTION Accelerometer Err Accelerometer calibration failure. Accelerometer ID Error Accelerometer fail to read ID information. Ballast Fault_1 Lamp over voltage. (See BALLAST ERROR NOTE page 36) Ballast Fault_2 Input voltage too high.
  • Page 53: Maintenance

    Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
  • Page 54: Specifications

    8 / 16 Bit Resolution Adjustable Movement 13,375 LUX 1,243 FC @49.2’ (15m) (3.0° Spot) DMX, RDM, Art-NET, and sACN Protocol Support 233,000 LUX 21,646 FC @49.2’ (15m) (2.0° Beam) Elation’s E-FLY™ Internal Wireless 11,500 LUX 1,068 FC @16.4’ (15m) (4.0° Wash)
  • Page 55: Colors And Gobos | Animation Wheel

    COLORS AND GOBOS ANIMATION WHEEL...
  • Page 56: Dimensional Drawings

    DIMENSIONAL DRAWINGS Drawing not to scale...
  • Page 57: Optional Accessories | Fcc Statement

    OPTIONAL ACCESSORIES ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp ELF001 E-FLY™ Wireless DMX Transceiver Single Road Case for PROTEUS HYBRID DRCPROHYBRID1 DRCPROHYBX2W Dual Road Case for PROTEUS HYBRID IP TESTER IP Fixture Vacuum and Pressure Leak Tester FCC STATEMENT This device complies with Part 15 of the FCC Rules.

This manual is also suitable for:

Proteus hybridPrh021

Table of Contents