ERROR CODES
ERROR CODES
Rotating Gobo
Rotation Er
xed Gobo
Wheel Er
Prism Wheel 1 Er
Prism Rotation
Wheel 1 Er
Prism Wheel 2 Er
Prism Rotation
Wheel 2 Er
Focus Er
Zoom Er
Error Codes are subject to change without any prior written notice.
The Rotating Gobo rotation movement is not located in the default
position after the reset. This message will appear after a fixture
reset if the gobo wheel's magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).
The Fixed Gobo Wheel movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
gobo wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Prism Wheel 1movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
gobo wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Prism Wheel 1 rotation movement is not located in the default
position after the reset. This message will appear after a fixture
reset if the gobo wheel's magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).
The Prism Wheel 2 movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
gobo wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Prism Wheel 2 rotation movement is not located in the default
position after the reset. This message will appear after a fixture
reset if the gobo wheel's magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).
The Focus movement is not located in the default position after the
reset. This message will appear after the reset of the fixture reset if
the magnetic-indexing circuit malfunctions (sensor failed or magnet
is missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Zoom movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo
wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).