Technical Data; Tetrix 300 Classic - EWM Tetrix 300 Classic Operating Instructions Manual

Table of Contents

Advertisement

Technical data

Tetrix 300 Classic

8
Technical data
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Tetrix 300 Classic
Welding current setting range
Welding voltage setting range
Duty cycle at 25 °C
Duty cycle at 40 °C
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Max. connected power
Recommended generator rating
cosϕ/efficiency
Insulation class/protection classification
Ambient temperature
Machine cooling
Workpiece lead
Dimensions L/W/H
Weight
EMC class
Constructed to standards
72
NOTE
TIG
5 A to 300 A
10.2 V to 22.0 V
300 A (80% DC)
270 A (100% DC)
300 A (60% DC)
250 A (100% DC)
10 min. (60% DC
6 min. welding, 4 min. break)
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 16 A
H07RN-F4G2.5
8.3 kVA
16.4 kVA
H/IP 23
-20 °C to +40 °C
50 mm
590 x 230 x 380 mm
IEC 60974-1, -3, -10;
MMA
20.2 V to 32.0 V
98 V
12.0 kVA
0,99
Fan
2
29 kg
A
;
099-000098-EW501
03.08.2011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 400-2 classic

Table of Contents