Design and function
TIG welding
5.7.3.1
Connecting the shielding gas supply
•
Place the shielding gas cylinder into the relevant cylinder bracket.
•
Secure the shielding gas cylinder using a securing chain.
Item
Symbol Description
1
2
3
4
•
Tighten the pressure regulator screw connection on the gas bottle valve to be gas-tight.
•
Screw gas hose connection crown nut onto the output side of the pressure regulator.
Item
Symbol Description
1
•
Connect crown nut of the shielding gas line to the G¼" connecting nipple.
28
0
Pressure regulator
Shielding gas cylinder
Output side of the pressure regulator
Cylinder valve
1
0
Connecting nipple G¼, shielding gas connection
Figure 5-6
Figure 5-7
099-000098-EW501