Design and function
Remote control
5.9.6

Foot-operated remote control RTF 1

ActivArc welding is not possible in combination with the RTF 1 foot-operated remote control.
Symbol
Meaning
Actuate foot-operated remote control (start welding process)
Operate foot-operated remote control (set welding current according to application)
Release foot-operated remote control (end welding process)
FFr
RTF ramp function
on
off
The RTF ramp function can be switched on and off in the machine control sub-menu
(see "Advanced settings > ramp function RTF" chapter).
52
Functions
Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
Start/stop welding operation (TIG)
FFr > off
I
FFr > on
I
start
Welding current runs in a ramp function at the specified main current
Welding current goes immediately to the specified main current
Figure 5-22
NOTE
I
end
t
099-000098-EW501