Technical data

Technical data
5.2
Technical data
Refer to the following tables for the key technical data of the valve:
Technical data: Valve
Designation
Size
Material of product contact parts
Fitting position
Technical data: Ambient temperatures
Designation
Valve
Initiator
Control Top T.VIS P-15
Product temperature and operating
temperature
Technical data: Compressed air supply
Designation
Air hose
Control air
24
Metric
Inch
Solid particle content:
Description
DN 25 to DN 150
1" to 6" OD
2" to 6" IPS
Stainless steel 1.4404
Any position, if valve and pipe system
can drain properly
Description
0 to 45 °C (32 ... 113 °F), standard
< 0 °C (32 °F): Use control air with low
dew point. Protect valve rods against
freezing.
< −15 °C: no solenoid valves in the
control top
< +50 °C: no solenoid valves in the
control top
-20 to +80 °C (-4 ... +176 °F)
-20 to +50 °C (-4 ... +122 °F)
depending on the sealing material
Description
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm
acc. to ISO 8573-1
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
430BAL011665EN_5
21.03.2023