18 Specifications

Fault
The shape of the
water jet has
changed.
Detergent is no lon‐
ger sucked in.
Connections with
pressure washer,
high-pressure hose,
spray gun or spray
lance are stiff.
The LED "BATTERY
INDICATION" flashes
red.
The activation key
flashes green.
17.2
Lubricating the seals
1
1
► Grease the seals (1) with grease for fittings.
18 Specifications
18.1
Pressure washer STIHL
RE 100.0 PLUS CONTROL
Version 220 V - 230 V / 50 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 2.1 kW
– Maximum permitted network impedance: 0.38
Ohm
– Protection class: II
– Degree of of electrical protection: IPX5
– Working pressure (p): 11 MPa (110 bar)
– Max. permissible pressure (p max.): 15 MPa
(150 bar)
– Max. water supply pressure (p in max.): 1 MPa
(10 bar)
– Max. water throughput (Q max.): 7.6 l/min
(450 l/h)
– Minimum water throughput (Q min.): 5.8 l/min
(350 l/h)
0458-004-0121-B
Cause
The nozzle is blocked.
The nozzle is worn.
The detergent container is empty.
The filter in the detergent bottle is dirty. ► Rinse out the filter under running
The gaskets of the connections have
not been greased.
The batteries in the control panel are
empty.
The connection between the pressure
washer and the control panel no longer
exists.
1
Remedy
► Clean the nozzle.
► Fit a new nozzle.
► Fill the detergent bottle with cleaning
agent.
water.
► Lubricate the gaskets.
► Install new batteries in the control
panel.
► Switch off the high-pressure washer.
► Reduce the distance between the
spray gun and the pressure washer.
► Switch on the pressure washer and
the control panel.
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode
(t in max): 40 °C
– Max. water temperature in suction mode:
20 °C
– sample inspection
– Length: 340 mm
– Width: 320 mm
– Height: 880 mm
– Length of high-pressure hose: 7 m
– Weight (m) with attached spraying device: 9
kg
– Approved batteries: AAA batteries (IEC size
LR03)
– Frequency band: ISM band 2.4 GHz
– Maximum RF power transmitted: 13 mW
– Signal range: approx. 16 m. The signal
strength depends on the ambient conditions
and the mobile terminal.
Parameters dependent on pressure have been
measured at an inlet pressure of 0.3 MPa (3
bar).
18.2
Extension Cords
If an extension cord is used, it must have a
ground wire and the wire gage of its conductors
must meet the following minimum requirements –
depending on the line voltage and length of the
extension cord:
If rated voltage on the rating label is 220V to
240V:
– Cord length up to 20 m: AWG 15 / 1.5 mm²
English
17.2
21