Stihl RE 100.0 PLUS CONTROL Instruction Manual page 20

Hide thumbs Also See for RE 100.0 PLUS CONTROL:
Table of Contents

Advertisement

English
Fault
The pressure washer
does not start when
switched on. The
electric motor buz‐
zes.
The pressure washer
switches off while in
operation.
The high-pressure
pump repeatedly
switches on and off
without squeezing the
spray gun trigger.
The working pressure
fluctuates or drops.
20
Cause
The circuit-breaker (fuse) or the resid‐
ual current circuit breaker has tripped.
There is an electrical overload or a
fault in the circuit.
The fuse rating of the socket is too
low.
The extension cord has an incorrect
cross-section.
The extension cord is too long.
The electric motor is too warm.
The mains voltage is too low.
The extension cord has an incorrect
cross-section.
The extension cord is too long.
The plug of the connecting cord or
extension cord has been pulled out of
the socket.
The circuit-breaker (fuse) or the resid‐
ual current circuit breaker has tripped.
There is an electrical overload or a
fault in the circuit.
The fuse rating of the socket is too
low.
The electric motor is too warm.
There is a leak in the high-pressure
pump, high-pressure hose or spray
attachment.
There is not enough water.
The nozzle is blocked.
The water intake screen or water filter
is blocked.
The high-pressure pump, high-pres‐
sure hose or spray attachment is leak‐
ing or faulty.
17 Troubleshooting
Remedy
► Look for cause of tripping and rem‐
edy it. Engage circuit-breaker (fuse)
or the residual current circuit
breaker.
► Switch off other loads connected to
the same circuit.
► Plug the connecting cable into a
socket with the correct fuse rating,
18.1.
► Use an extension cord with an ade‐
quate cross-section,
► Use an extension cord with the cor‐
rect length,
18.2
► Allow the pressure washer to cool
for 5 minutes.
► Clean the nozzle.
► Squeeze and hold the spray gun
trigger and switch on the pressure
washer.
► Switch off other loads connected to
the same circuit.
► Use an extension cord with an ade‐
quate cross-section,
► Use an extension cord with the cor‐
rect length,
18.2
► Plug in mains plug of connecting
cord or extension cord.
► Look for cause of tripping and rem‐
edy it. Engage circuit-breaker (fuse)
or the residual current circuit
breaker.
► Switch off other loads connected to
the same circuit.
► Plug the connecting cable into a
socket with the correct fuse rating,
18.1.
► Allow the pressure washer to cool
for 5 minutes.
► Clean the nozzle.
► Ask a STIHL servicing dealer to
inspect the pressure washer.
► Open water tap fully.
► Make sure that a sufficient quantity
of water is available.
► Clean the nozzle.
► Clean water intake screen and water
filter.
► Ask a STIHL servicing dealer to
inspect the pressure washer.
18.2
18.2
0458-004-0121-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE 100.0 PLUS CONTROL and is the answer not in the manual?

Questions and answers

Table of Contents