Maico ER 60 E Mounting And Operating Instructions page 14

Recess-mounted exhaust air system
Hide thumbs Also See for ER 60 E:
Table of Contents

Advertisement

● Energy-saving motor with thermal overload
protection. This switches itself off in the
event of overheating and then back on
again automatically after cooling down.
● The fans may be subject to jet water in
areas 1 and 2 (DIN VDE 0100-701:
2008-10 and/or HD 60 364-7:2007).
Unit type
ER 60 E
ER 100 E
ER 60 EVZ, ER 100 EVZ
ER 60 EG, ER 100 EG
ER 60 EH, ER 100 EH
Tolerance of time details max. + 20 %.
7.3.3 ER-UP controls (circuit board types)
ER-UP fans are available in various models
and with various unit properties. These
depend on the control/circuit board type
used in the fan insert [3].
Circuit board models
● EVZ model: With start delay and overrun
● EG model: With base load circuit.
● EH model: Barrier-free. With humidity
Circuit board
Start delay
type
Standard board
Standard board
VZ board
G board
H board
7. Product information
The circuit variants and functions
suited to the circuit board type are
described in chapter 22.
time.
Continuous operation at 35 m³/h, high
speed
can be switched with
(full load)
optional switch.
control (fully automatic). Overrun time
controlled by program (15 minutes at full
load). Can also be operated manually with
optional switch.
Not suitable for second
room ventilation.
Overrun
[s]
time
[min]
50
15
15
Can be
Power
controlled
cable
by speed
[mm²]
no
3 x 1.5
yes
3 x 1.5
no
5 x 1.5
no
5 x 1.5
no
5 x 1.5
11