13. Electrical connection
NOTICE
Unit damage caused by EVZ and EH
units touching ESD sensitive
components on the electronic circuit
board.
 Avoid direct touching of the components
or contact surfaces.
NOTICE
Damage to the unit if connected
incorrectly. For example, if an electric
load is connected to terminal 4 or if
connected to 2 phases.
 Connect the unit as shown in the wiring
diagrams in chapter 22.
 Do not connect additional consumers
to terminal 4.
Notes
● Always note the relevant specifications
for electrical installations and when fitting
equipment. In Germany, observe DIN VDE
0100 and the corresponding parts in
particular. In rooms with baths or shower
units, for example, this would be Part 701.
● The electrical connection is only permitted
by trained electricians.
● The electrical connection can be under-
taken upon installation of the ER-UP
housing.
● Observe ambient conditions ( chapter 8)
and technical data ( chapter 9).
● Note permitted duct cross-section of
max. 1.5 mm².
● Only connect the unit to a permanent
electrical installation.
● The degree of protection is only
guaranteed:
● if installation is undertaken correctly,
● if the power cable is correctly guided
through the intended cable grommet,
● if fan unit is correctly engaged in
ER-UP housing and
● if cover [7] is closed and engaged.
24
13.1.1 Connect the unit electrically
1. Switch off mains fuse, secure and fit
warning sign.
2. Remove plaster protective cover.
3. Cut off and insulate PE conductor and
individual cable cores that are not
required!
4. Remove power cable surround and cut to
length according to Figure 10.
5. Wire power cable to the terminal box
according to the wiring diagram in
chapter 22.
Mark the fan type on the wiring diagram in
the recess-mounted housing. This
prevents mistakes during final installation,
for example, if different fan inserts are
fitted in the system.
6. Insert plaster protective cover.
We recommend keeping these
mounting and operating instructions
until final installation in the ER-UPD
housing.

Advertisement

Table of Contents
loading

Table of Contents