Open the VLS door and remove the magazine by
pressing the Magazine Release.
p
Press the UNLOAD button on the drive front panel (see
figure 13 for location).
p
Close the VLS door.
p
On the VLS front panel, first press ALT, then the OPEN
DOOR keys.
p
Open the VLS door and remove the ejected cartridge
from the drive.
p
If the cartridge was loaded into drive from the magazine
place it back in the correct slot.
p
Replace the magazine onto the carriage.
p
Close the door. You can now initiate the load procedure.
Removing a Cartridge Loaded in the Drive Using
the Diagnostics Menu
Use this procedure to load the magazine if there is a
cartridge in the drive, and the cartridge was loaded by either
the application software or by using the Diagnostics Menu.
p
Open the VLS door.
p
Press the UNLOAD button on the drive front panel (see
figure 13 for location). The drive will prepare the
cartridge for ejection.
p
Close the VLS door.
p
To access the Diagnostics Menu, press the MENU
button. The display will read as follows: