Environmental
0
Conditions

Preparing for the Installation

Providing Necessary
0
Tools and Equipment
Taking ESD
0
Precautions
6
The installation site must have the following environmental conditions:
Humidity: 20%-80% non-condensing
Temperature: 15°C-32°C (59°F-90°F)
Altitude: sea level to 3048 meters (10,000 feet)
These environmental conditions apply when the library is in operation.
For additional library specifications (including environmental
Note:
requirements during shipping and storage), see appendix A in the
Quantum PX720 Series User's Guide.
Before you begin the installation procedure in this section, make the following
preparations as described in these sections:
Providing necessary tools and equipment for installation

Taking ESD precautions

Provide the following tools for unpacking the library:
#2 PHILLIPS® screwdriver
Snips for metal bands
Safety goggles
3/8 open-ended wrench or socket
3/4 inch open-end wrench (included in accessory kit)
3/16 in. Allen® wrench
7/16 inch wrench or socket
Provide the following tools for leveling the library:
Carpenter's level
Some components within the PX720 library contain static-sensitive parts. To
avoid damaging these parts while performing installation procedures, always
observe the following precautions:
Keep the library turned off during all installation procedures.
Keep the library power cord plugged into a grounded power outlet
except when working with AC electrical components.