Environmental Conditions

Preparing for the Installation

Providing Necessary
Tools

Taking ESD Precautions

Weight
Air Clearance
0
The installation site must have the following environmental conditions:
Humidity: 20%-80% non-condensing
Temperature: 10°C-35°C (50°F-95°F)
Altitude: 0 to 10,000 feet (0 to 3048 meters)
These environmental conditions apply when the DX-Series system is in operation.
Note:
For additional specifications, refer to the Quantum DXi3500 and DXi5500 User's
Guide (PN 81-81701)
Before you begin the installation procedure in this section, make the following
preparations as described in this section:

Providing Necessary Tools

Taking ESD Precautions
Provide the following tools for unpacking and installing the DXi3500 and DXi5500
0
systems:
#1 PHILLIPS® screwdriver
#2 PHILLIPS screwdriver
#1 Flat head screwdriver
Antistatic wrist strap included in accessory kit
0
Some components within the DXi3500 and DXi5500 systems contain static-sensitive parts.
To avoid damaging these parts while performing installation procedures, always observe
the following precautions:
Keep the DXi3500/DXi5500 system turned off during all installation procedures.
Use an antistatic wrist strap (included in the accessory kit).
Keep static-sensitive parts in their original shipping containers until ready for
installation.
Preparing for the Installation
DXi3500
50 lbs (22.68 kg)
Open 4 in (10.2 cm) behind unit for proper air flow
DXi3500 and DXi5500
DXi5500
122 (55.34 kg)
3