8-4. Accessing User Setup Menu: DC TIG And Lift-Arc

2
USER
HF START
Schedule 1
TUNG
RMT
.
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
Or
LIFT ARC
Schedule 2
3/32
STD
1
Menu Button
Press and hold Menu button for ap-
proximately 2 seconds to access
machine configuration menus. Use
1
Menu button to cycle through para-
meters that can be set.
2
Parameter Display
3
Setting Display
4
Encoder
Rotate Encoder to adjust paramet-
er setting.
.
To exit menu, press and hold
Menu button until Menu Off is
displayed.
Tungsten Diameter Selection:
Each tungsten size has preset starting parameters
specific to that diameter for optimized starting.
Range is 0.020 in.−1/8 in. or 0.5 mm−3.2 mm. To
manually set starting parameters, see Section 17-3.
Trigger Mode Selection (See Section for 11-4 for
additional trigger function options).
[RMT] [STD]
Typical setting for a remote foot or hand control.
RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled
with a remote potentiometer, or it can be set at the
control panel.
[RMT] [HOLD]
Remote control required. Allows the operator to
weld without holding the trigger closed. To start the
weld, operator presses and releases trigger. To stop
the weld, the operator again presses and releases
the trigger. In this mode, only the output contactor is
controlled by the remote control. Amperage must be
set on the control panel. (see Section 11-4).
[OUT] [ON]
Output on. (Lift only)
!
Weld output terminals are energized at all
times when displays read [OUT] [ON].
No remote control or trigger required. Amperage
can be controlled at the control panel or with a re-
mote potentiometer. Blue output on LED illuminates
to indicate output is on. Not valid with HF start.