8-5. Accessing User Setup Menu: DC Stick

2
USER
HF START
Schedule 1
HOTS
OUT
OM-270536 Page 46
.
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
LIFT ARC
Schedule 2
Or
ON
ON
1
Menu Button
Press and hold Menu button for ap-
proximately 2 seconds to access
machine configuration menus. Use
1
Menu button to cycle through para-
meters that can be set.
2
Parameter Display
3
Setting Display
4
Encoder
Rotate Encoder to adjust paramet-
er setting.
.
To exit menu, press and hold
Menu button until Menu Off is
displayed.
Arc Starting Mode Selection:
[HOTS] [ON]
Provides additional amperage while striking the elec-
trode to prevent the electrode from sticking.
[HOTS] [OFF]
No additional starting amperage to assist in starting the
electrode.
Trigger Mode Selection:
[RMT] [STD]
Typical setting for a remote foot or hand control.
RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled
with a remote potentiometer, or it can be set at the
control panel.
[OUT] [ON]
!
Weld output terminals are energized at all
times when displays read [OUT] [ON].
No remote control or trigger required. Amperage can
be controlled at the control panel or with a remote po-
tentiometer . Blue output on LED illuminates to indic-
ate output is on.