Island hood

Advertisement

Quick Links

EN
Island hood
Skyline Curve / Skyline Edge
EN
Operating and installation instructions for the models
ƒ BIH 95 SKC
ƒ BIH 95 SKE
ƒ BIH 95 SKE Light
ƒ BIH 115 SKC
ƒ BIH 115 SKE
ƒ BIH 115 SKE Light
ƒ BIH 135 SKC
ƒ BIH 135 SKE Sound
6006241_0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Skyline Curve and is the answer not in the manual?

Questions and answers

Summary of Contents for Berbel Skyline Curve

  • Page 1 Island hood Skyline Curve / Skyline Edge Operating and installation instructions for the models ƒ BIH 95 SKC ƒ BIH 115 SKC ƒ BIH 135 SKC ƒ BIH 95 SKE ƒ BIH 115 SKE ƒ BIH 135 SKE Sound ƒ BIH 95 SKE Light ƒ...
  • Page 2 Document information Symbol clarification - text ☞ Handling requirement Operating and installation instructions for: y BIH 95 SKC E02 island hood y Listing y BIH 95 SKE E02 island hood y BIH 95 SKE Light E02 island hood D Reference to another point in this document y BIH 115 SKC E02 island hood y BIH 115 SKE E02 island hood  Reference to other documents that should be observed...
  • Page 3: Table Of Contents

    Product variants......5 2.3.1 Skyline Curve island hood .....5 2.3.2 Skyline Edge island hood .
  • Page 4: Safety Information

    Safety information Safety information General safety instructions D WARNING! Proper intended use Hazard through a disregard of the operating and installation instructions! The device serves to extract cooking vapours. This manual contains important information for the safe The device is intended exclusively for private domestic use. handling of the device.
  • Page 5: Product Information

    60 minutes of total operating time. Product variants 2.3.1 Skyline Curve island hood Cooking vapours are drawn through a gap and into the hood where they are accelerated and routed through bends. The resultant centrifugal force ejects particles of dirt (e.g.
  • Page 6: Skyline Edge Island Hood

    Product information 2.3.2 Skyline Edge island hood 2.3.3 Ceiling consoles Variants with all-round effect lighting 230 V y With stainless steel cover y With glass cover y With glass cover and integrated ceiling effect lighting  The relevant documentation must be observed for ceiling consoles with lowering capability.
  • Page 7: Product Overview

    Product information Product overview A Ceiling mounting plate B Screwed end C Mounting sleeve D Support cable E Cover for ceiling mounting plate F Wieland socket G Bracket A Ceiling console comprising a ceiling mounting plate and H Mains cable with Wieland plug a cover Lock nut for ceiling mounting plate B Hood body with effect lighting...
  • Page 8: Scope Of Delivery

    Technical data Information on the model (e.g. serial number, year of construction) is quoted on the front panel. D “2.4 Product overview” (page 7). 2.6.1 Skyline Curve island hood 230 V / 230 V / Connection voltage 50 Hz 50 Hz Total power max.
  • Page 9: Skyline Edge Island Hood

    Product information 2.6.2 Skyline Edge island hood Variants with surface effect lighting Variants with all-round effect lighting 230 V / 230 V / Connection voltage 50 Hz 50 Hz Connection 230 V / 230 V / 230 V / 230 V / Total power max.
  • Page 10: Installation

    Installation Installation Requirements for the installation location D WARNING! Safety information for installation Risk of death due to improper installation! Disregard of the ambient conditions can lead to hazardous situations, e.g. in the handling of electrical power or gas. D WARNING! ☞...
  • Page 11: Installation Procedure

    Installation Installation procedure 3.4.2 Unpack the device Short overview: D ATTENTION! 1. Preparation for installation 2. Unpack the device Hazard of glass breaking or other damage due to 3. Install the ceiling mounting plate incorrect handling! 4. Hang the device in place The device and its surfaces can be damaged when being 5.
  • Page 12: Install The Ceiling Mounting Plate

    Installation 3.4.3 Install the ceiling mounting plate The device is designed to be hung on ceilings. When mounting to a solid ceiling: ☞ Make sure that the ceiling has sufficient load bearing capacity. ☞ Ensure that the ceiling is level and horizontal. ☞...
  • Page 13 Installation ☞ Screw the nuts and the washers onto the bolt anchors in the slots. ☞ Ensure that the ceiling mounting plate is aligned parallel to the hob’s front edge. ☞ Tighten the nuts cross-wise using the spanner. ☞ Ensure that all nuts are fully tightened. ☞...
  • Page 14: Hang The Device In Place

    Installation Variants with integrated ceiling effect lighting ☞ Have two persons lift the hood body. ☞ Align the hood body. ☞ Observe the voltage specifications on the ratings plate. y The distance to the ceiling mounting plate must be ☞ Connect the cable to the connection terminal from the less than 800 mm.
  • Page 15 Installation D WARNING! D WARNING! Risk of injury due to the device falling down! Risk of death due to electric shock! Loosen the mounting sleeves to align the device. If the Touching live parts can cause an electric shock, burns or fastening sleeves are loosened too far, the support cable death.
  • Page 16 Installation Variants with integrated ceiling effect lighting ☞ Plug the Wieland plug into the Wieland socket. ☞ Guide the glass plate fully into the ceiling console. ☞ Lower the glass plate from above onto the seal. All variants ☞ Check that the mains cable and the electrical connection cable are not kinked, crushed or damaged.
  • Page 17: Set The End Positions

    Installation 3.4.5 Set the end positions ☞ Switch the electricity supply on. The remote control is used to set the end positions. When using the recirculated air filter permalyt BUR BIH  Observe the instruction manual for the remote control. (optional): When the device is connected to the power supply for the first time, this is confirmed by an acoustic signal.
  • Page 18: Set Colour Temperature

    Installation 3.4.6 Set colour temperature The device and the BFB 6bT remote control must be connected once. The colour temperature of the hob lighting, the effect D “4.2 Operating the device” (page 19). lighting and the ceiling effect lighting can be set to the colour temperature of the kitchen environment.
  • Page 19: Operation

    Operation Operation Cooking oils and fats have different smoke points. The smoke point is the temperature at which smoke clearly develops over the hot oil or fat. The smoke can settle on furniture, the fronts of kitchen units and the ceiling. Safety information for operation ☞...
  • Page 20: Cleaning

    Cleaning Cleaning Cleaning procedures The device draws in dirt particles (e.g. grease and oil particles) with the air from the room. The dirt particles are separated off Safety information for cleaning and collected in the upper section, the lower section and in the Capillar Trap.
  • Page 21 Cleaning D CAUTION! Danger of injuries due to device edges! When removing and replacing the lower section or the cross flow, fingers may become trapped and crushed. ☞ Move the device parts slowly and carefully. D ATTENTION! Danger of damage due to falling parts! The lower section and the Capillar Trap can fall down when being removed and damage the hob, the kitchen furnishings or other objects.
  • Page 22: Maintenance

    Maintenance Maintenance Maintenance intervals y When the control indicator blinks - every 1000 fan operating hours.  Observe the instruction manual for the remote control. Safety information for maintenance y With odours in the exhaust air. y With daily use, after 24 months at the latest. D WARNING! y With occasional use, after 36 months at the latest.
  • Page 23: Fault Rectification

    Maintenance Fault rectification Possible faults are described below: Description of the fault. y Possible cause. ☞ Remedy. Fan and lighting do not work. y No power supply. ☞ Check that the all-pole mains switch is connected. ☞ Switch the mains switch on. y The breaker may have been tripped or is defective.
  • Page 24 Maintenance Moisture in the device. y Dripping or splashing water has penetrated the device. y Liquid (e.g. from vases, bottles on the device) has penetrated the device. ☞ Immediately shut off the power supply, by removing the fuse. ☞ Make sure that the power supply cannot be unintentionally reconnected.
  • Page 25: Dismounting

    Dismounting Dismounting ☞ Have two persons hold the body. ☞ Have a third person unscrew the lock nuts (counter nuts) ☞ Move the device into a position where the distance to the for the support cable on the fastening sleeves. ceiling console is no more than 1150 mm.
  • Page 26: Disposal

    Disposal Disposal Dispose of filter filling ☞ Dispose of the charcoal in accordance with the local applicable Waste Disposal Act (EU waste code 061302). Dispose of packaging Dispose of the device D ATTENTION! Risk of environmental damage due to improper disposal D ATTENTION! of the packaging! Risk of environmental damage due to improper disposal...
  • Page 27: Annex

    D-48432 Rheine declares that the following products comply with the provisions of the EU Directives cited above: Contact Skyline Curve / Skyline Edge island hood If you have any questions or suggestions, please select from the following options: Type/model series:...
  • Page 28 6006241_0 30.05.2022...

This manual is also suitable for:

Skyline edgeSkyline edge lightBih 95 skcBih 95 skeBih 95 ske lightBih 115 skc ... Show all