Berbel Ergoline 2 BKH 60 EG-2 Operating And Installation Instructions

Berbel Ergoline 2 BKH 60 EG-2 Operating And Installation Instructions

Headroom hood
Table of Contents

Advertisement

Quick Links

EN
Headroom hood
Ergoline 2
EN
Operating and installation instructions for the models
ƒ BKH 60 EG-2
ƒ BKH 70 EG-2
ƒ BKH 80 EG-2
ƒ BKH 90 EG-2
ƒ BKH 110 EG-2
ƒ BKH 120 EG-2
6004847_b

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ergoline 2 BKH 60 EG-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Berbel Ergoline 2 BKH 60 EG-2

  • Page 1 Headroom hood Ergoline 2 Operating and installation instructions for the models ƒ BKH 60 EG-2 ƒ BKH 110 EG-2 ƒ BKH 70 EG-2 ƒ BKH 120 EG-2 ƒ BKH 80 EG-2 ƒ BKH 90 EG-2 6004847_b...
  • Page 2 Document information Symbol clarification - text ☞ Handling requirement Operating and installation instructions for: y Headroom hood BKH 60 EG-2 E02 y Listing y Headroom hood BKH 70 EG-2 E02 y Headroom hood BKH 80 EG-2 E02 D Reference to another point in this document y Headroom hood BKH 90 EG-2 E02 y Headroom hood BKH 110 EG-2 E02  Reference to other documents that should be observed...
  • Page 3: Table Of Contents

    Table of contents Safety information ......4 Cleaning ........26 Proper intended use .
  • Page 4: Safety Information

    Safety information Safety information General safety instructions D WARNING! Proper intended use Hazard through a disregard of the operating and installation instructions! The device serves to extract cooking vapours. This manual contains important information for the safe The device is intended exclusively for private domestic use. handling of the device.
  • Page 5: Product Information

    Product information Product information BackFlow technology (optional) y Condensate or droplet formation on the decorative panel (e.g. if steam touches the cold surface) is prevented by a vent installed from the bottom to the top. Functional principle y Part of the vented air quantity is fed to the back of the extractor hood, blown over the glass front and directed into the suction gap.
  • Page 6: Operating Modes

    Product information Operating modes 2.2.3 Hybrid mode The device is suitable for the following operating modes: In hybrid mode, it is possible to select flexibly between y Recirculated air mode recirculated air mode and extracted air mode. y Extracted air mode y Hybrid mode In extracted air mode, the cleaned room air is routed to the outside through the wall box which opens automatically.
  • Page 7: Product Overview

    Product information Product overview Scope of delivery A Chimney B Hood body C Upper section with bulging edge (removable) D Lower section (removable) E Capillar Trap (removable) - behind the lower section F Front panel made of glass G Control panel H Effect lighting - on the rear of the hood body Hob lighting Type plate - on the inside of the front panel...
  • Page 8: Technical Data

    Product information Technical data 230 V / 230 V / 230 V / Connection voltage 50 Hz 50 Hz 50 Hz 230 V / 230 V / 230 V / Total power 187 W 193 W 193 W Connection voltage 50 Hz 50 Hz 50 Hz...
  • Page 9: Installation

    Installation Installation Requirements for the installation location D WARNING! Safety instructions for installation Risk of death due to improper installation! Disregard of the ambient conditions can lead to hazardous D WARNING! situations, e.g. in the handling of electrical power or gas. ☞...
  • Page 10: Requirements For Individual Operating Modes

    Installation Requirements for individual operating modes Requirements for the exhaust air ducting (only for extracted air mode or hybrid mode) Further accessories may be required depending on the operating mode. D WARNING! Fire hazard and asphyxiation hazard due to improper 3.3.1 Requirements for recirculated air mode installation! When using the exhaust air ducting with other devices y Recirculated air filter at the fan outlet.
  • Page 11: Installation Procedure

    Installation Installation procedure 3.5.2 Unpack the device Short overview: D ATTENTION! 1. Preparation for installation 2. Unpack the device Hazard of glass breaking or other damage due to 3. Removing the lower section, bulging edge and incorrect handling! Capillar Trap The device and its surfaces can be damaged when being 4.
  • Page 12: Edge And Capillar Trap

    Installation 3.5.3 Removing the lower section, bulging edge and The bulging edge is attached and held in the device by Capillar Trap magnets. D ATTENTION! Danger of property damage through falling parts! When moving the device, the front panel may open and parts lying inside could fall out.
  • Page 13: Hang The Device In Place

    Installation D WARNING! 3.5.4 Hang the device in place Risk of death due to explosions or electric shock! The device is designed to be hung on walls. The chimney can Drilling through gas, water or electrical lines can lead to be adapted to the ceiling height by pulling it out.
  • Page 14 Installation a = 7 b = 3-6 The top fastening screws should only be tightened once the ☞ Hang the device on the mounting points. device has been aligned. The lower fastening screws prevent the device pulling away from the wall and are no longer accessible after the device is hung in place.
  • Page 15: Connect Accessories

    Installation 3.5.5 Connect accessories Wall box y The wall box is closed when the control contacts are Depending on the installation situation, available accessories open. may be connected to the hood, e.g.: y The wall box is open when the control contacts are y Wall box closed.
  • Page 16: Install Filter

    Installation 3.5.7 Install filter (with recirculating and hybrid Hybrid mode - exhaust air upwards operation) The BackFlow port (Ø 150 mm) is located on the fan housing as an aid for the installation of the filter. The filter is placed correctly when the bottom edge of the filter is parallel to the top edge of the fan‘s housing and the gap is approximately 3 mm wide.
  • Page 17: Connect Exhaust Air Ducting (With Exhausted Air And Hybrid Operation)

    Installation 3.5.8 Connect exhaust air ducting (with exhausted Hybrid mode air and hybrid operation) Extracted air mode without BackFlow technology The BackFlow port is not used. When connecting a flexible hose, it is possible to use a tight-fitting pipe as an intermediate piece.
  • Page 18: Establish Electrical Power Supply

    Installation 3.5.9 Establish electrical power supply Recirculating mode and hybrid mode The ventilation slots are located at the top and are not ☞ Observe the voltage specifications on the rating plate. covered. Extracted air mode The inner chimney duct can be drawn out and re-inserted upside-down in order to cover the ventilation slots.
  • Page 19: Insert The Capillar Trap, Bulging Edge And Lower Section

    Installation 3.5.11 Insert the Capillar Trap, bulging edge and lower section After the installation, the parts lying inside should be re-fitted. ☞ Insert the lower section horizontally into the device until it reaches the rear stop. ☞ Insert the Capillar Trap into the mounting slot in a bow movement with both hands.
  • Page 20: 3.5.12 Check And Carry Out Commissioning

    Installation 3.5.12 Check and carry out commissioning D ATTENTION! Risk of disruptions due to moisture in the device! If the device is moved from a cold environment into a hot one, condensation may form inside. ☞ Wait about 2-3 hours before bringing the device into service.
  • Page 21: Operation

    Operation Operation Measures to ensure a sufficient supply of fresh air: ☞ Open the windows. ☞ Open the doors. ☞ Ensure that the window contact switch and the wall box Safety instructions for operation are installed and ready for operation. ☞...
  • Page 22: Operating The Device

    Operation Operating the device 4.2.1 Normal operation The device is operated from the control panel. D WARNING! Fire hazard due to grease residue! In operation grease residue, which is highly inflammable, collects in and on the device. ☞ Clean the device properly. D “5.
  • Page 23: Extraction Mode / Recirculated Air Mode

    Operation 4.2.2 Extraction mode / recirculated air mode 4.2.4 Window contact switch changeover If a window contact switch is connected to the device, this If the device is configured for hybrid mode, it is possible to monitors whether the corresponding window is open or switch between extraction mode and recirculated air mode closed.
  • Page 24: Effect Lighting

    Operation 4.2.6 Effect lighting Button Function The effect lighting is dimmable and is equipped with energy- The device is switched on, and any power saving LEDs. The lighting can be used independently of the level is selected. fan. It can be switched on when the device is on. It can be switched off at any time.
  • Page 25: Configuring The Device

    Operation Configuring the device Button Function Automatic run-on. Button Function As delivered, the function is turned on. The device is turned on. ☞ Touch the button one time. ☞ Touch and hold 1x button for longer than Button glows brightly: 5 seconds until the configuration steps are Automatic run-on is activated.
  • Page 26: Cleaning

    Cleaning Cleaning Cleaning procedures The device draws in dirt particles (e.g. grease and oil particles) with the air from the room. The dirt particles are separated Safety information for cleaning and collected in the upper section, on the bulging edge, in the lower section and in the Capillar Trap.
  • Page 27 Cleaning Lower section The lower section is secured in the end positions and can only be removed in a horizontal position. ☞ Pull the bulging edge from the upper section. ☞ Clean the upper section with a soft, moist cloth. ☞...
  • Page 28: Maintenance

    Maintenance Maintenance 6.2.2 Replacing filter filling (with recirculating and hybrid mode) Odours are trapped in the filter filling in the recirculating air Safety instructions for maintenance filter or hybrid filter. The odour-free, cleaned room air is fed back into the room. D WARNING! Recirculating air filters and hybrid filters are maintenance-free Hazard through a disregard of the maintenance...
  • Page 29 Maintenance Removing the hybrid filter ☞ Slide the inner chimney duct downwards. ☞ Remove the exhaust pipe from the hybrid filter. ☞ Lift the filter at least 30 mm. ☞ Remove the filter to the front.  The replacement of the filter filling is carried out as described in the associated instructions.
  • Page 30: Fault Rectification

    Maintenance Fault rectification Control panel does not react after being touched several times. y The control panel is soiled. Possible faults are described below: ☞ Clean the control panel. Description of the fault. D “5. Cleaning” (page 26). y Possible cause. y The device software requires a restart.
  • Page 31: Dismounting

    Dismounting Dismounting D WARNING! Risk of death due to electric shock! Touching live parts can cause an electric shock, burns or death. ☞ Disconnect all poles of the power supply for the device. ☞ Ensure that the voltage supply is and remains disconnected while the following work is in progress.
  • Page 32: Disposal

    Disposal Disposal Dispose of the device D ATTENTION! Dispose of packaging Risk of environmental damage due to improper disposal of the device! The device is subject to the European Directive 2012/19/EU D ATTENTION! and should not be disposed of with household waste. Risk of environmental damage due to improper disposal ☞...
  • Page 33: Annex

    Annex Annex BKH 110 EG-2 E02 BKH 120 EG-2 E02 Product data sheet berbel BKH 110 EG-2 E02 berbel BKH 120 EG-2 E02 In accordance with article 3 section 1 b point ii of the Regulation (EU) No. 65/2014 The information on the energy label applies to extraction in extracted air mode without BackFlow technology.
  • Page 34 Annex Annual energy consumption Annual energy consumption 36.2 36.4 34.2 34.2 38.6 38.6 in kWh in kWh Energy efficiency index (EEI) 54.7 54.8 50.9 Energy efficiency index (EEI) 50.9 54.1 54.1 EEI Hood Class EEI Hood Class FDE Hood 29.5 29.5 32.9 FDE Hood...
  • Page 35: Contact

    Annex Contact If you have any questions or suggestions, please select from the following options: Post: berbel Ablufttechnik GmbH Sandkampstraße 100 D-48432 Rheine Telephone: +49 (0) 5971 / 80 80 9 - 0 Mon to Thu 8:00 – 17:30 hrs and Fri 8:00 –...
  • Page 36 6004847_b 03.06.2022...