D-Channel Configuration - Nortel Media Gateway 1000E PRI Installation And Comissioning Manual

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

80 Configure an E1/T1 card
4
5
6
Table 15
DPNSS/DASS loop configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
CEQU
CFN
YES
...
DDCS
loop
MG_CARD
supl sh card
D-channel configuration
Table 16 "PRI/NI2 D-channel interface configuration (LD 17)" (page 81)
Table 17 "PRI2/Euro D-channel interface configuration (LD 17)" (page 83)
show the D-channel interface configuration in LD 17 needed to support
PRI/NI2 and PRI2/EURO D-channel interfaces.
The example given in the tables is specific to EURO and NI2 interfaces.
However, PRI D-channel in the PRI Gateway is also supported on other
interface types as well.
For CTYP=MSDL configuration, CS 1000 Release 5.0 software is flexible.
An E1/T1 span can use port 0 or port 1 of the DDCH along with MG_CARD
prompt added to support the Media Gateway Controller (MGC).
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
PASS?
Enter the default password:
0000
Access LD 17. Enter the command:
LD 17
Enter the responses shown in
configuration (LD 17)" (page
Description
Change existing data.
Make changes to common equipment parameters.
Common equipment.
The PRI loop number for the new DPNSS/DASS link.
The physical card for the DPNSS/DASS loop association
to the PRI Gateway.
The format is superloop, shelf, card.
Note: If using the NTAK93AB daughterboard, even card
numbers are applicable (2, 4, 6, 8). If using the onboard
DPNSS/DASS, odd and even numbers are applicable (1, 2,
3, 4, 5, 6, 7, 8).
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Table 15 "DPNSS/DASS loop
80).
—End—