Pri Startup - Nortel Media Gateway 1000E PRI Installation And Comissioning Manual

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

4
5
6
Table 34
DDCH maintenance commands (LD 96)
Command
DIS DCH x
ENL DCH x (FDL)
EST DCH x
RLS DCH x
RST DCH x
STAT DCH (x)
STAT MON (x)
DIS MSDL sl s c (ALL)
ENL MSDL sl s c (FDL, ALL)
RST MSDL sl s c
STAT MSDL sl s c (X (full))

PRI startup

Use
and DDCH from a disabled state to an operational state.
Procedure 49
Starting up the PRI
Step
1
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Enter the default password:
0000
Access LD 96. Enter the command:
LD 96
Enter the commands shown in
commands (LD 96)" (page
Note: In this table, x = the DCH number, and X = the MSDL
address (loop shelf card).
Description
Disable DCH x.
Enable DCH x and attempt to establish the link, and force download
to MSDL.
Establish multiple frame operation on D-channel x.
Release D-channel x.
Reset D-channel x, inhibit signaling.
Get status of one or all D-channels.
Display the incoming and outgoing monitoring status of one or all
D-channels.
Disable DCHI card sl s c.
Enable DCHI card sl s c, with or without Force Download.
Reset MSDL card sl s c.
Get MSDL status sl s c, or a FULL STATUS.
Procedure 49 "Starting up the PRI" (page 123)
Action
Check the status of all PRI/PRI2 cards.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Table 34 "DDCH maintenance
123).
—End—
to take the PRI/PRI2
PRI startup 123