62 Configure the Media Gateway Controller and DSP daughterboards in a PRI Gateway
Procedure 12
Configuring the Media Gateway Controller on a Call Server using LD 97
Step
1
2
3
4
5
6
Table 10
Media Gateway Controller configuration (LD 97)
Prompt
Response
REQ
aaa
TYPE
Supl
0–252
SUPL
SLOT
<CR>
SUPT
IPMG
The following prompts are for IPMG superloops only.
IPR0
nn.nn.nn.nn
IPMG_TYPE
MGC
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
0000
Access LD 97. Enter the command:
LD 97
Enter the responses shown in
configuration (LD 97)" (page
Description
Request (aaa = CHG, NEW)
Superloop
Superloop number. Add prefix X to delete.
Select default.
IP Media Gateway
Shelf 0 IPMG Uplink IP address. <CR> to skip to IPR1 when
configuring new superloop; X to remove IPR0, DES0, and
ZONE0 data.
IPMG is controlled by MGC card.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Table 10 "Media Gateway Controller
62).