Chapter 3. Charging Batteries - IDEAL MSC-13K-B Manual

Mobile column lift set capacity 13,200lbs / each column
Table of Contents

Advertisement

4.
Fix the reel on the base by the screw. (Fig 4-1d)
5.
Put the cable plug into the socket. (Fig 4-1e)
6.
Repeat the above steps for the other three columns
3. CHARGING BATTERIES
After one day's operation or the battery indicator [22] shows the voltage is low, it is
suggested to charge the batteries. Different batteries need different charging time.
Please refer to the manual of the battery.
a) Move the columns near the AC power supply ports on the wall.
b) Connect the charger to the AC power supply. (Fig. 10)
c) Turn the power switch to the right position (CHARGE) on each column.
d) While charging, the red CHARGING indicator will be lighted. After the batteries
are fully charged (about 10 hours), the green FINISH indicator will be on and red
indicator will go off.
Battery Charger Socket
Fig. 4-1d
Switch
Fig. 10
9
Nov. 2021
MSC-13K
Fig. 4-1e
Charger Indicator