IDEAL MSC-13K-B Manual page 22

Mobile column lift set capacity 13,200lbs / each column
Table of Contents

Advertisement

greater than 2" (50mm), the column will be suspended automatically.
3. Times and minutes
When in ALL mode, there are time and
min on the bottom line on the screen. It
shows from the beginning (software
installed) how many times the motors
have been started how long it worked
for pumping up the cylinder.
4. Locked column
When one button is pressed down or if
it is within 2 seconds just after it is
released, (the red STOP light is on) ,
any button be pressed down, that
control box of the later button will be
locked.
To unlock, any button on other column has to be pressed one time.
5.4 EMERGENCY STOP AND LOWERING
In emergency situations it is possible to stop the lifting
columns manually by pushing the emergency button.
NOTE:
If the motor keeps running after EMERGENCY
button is pressed down, please immediately turn
off the battery switch to stop it.
Manual lowering must be performed by a qualified engineer only. (Refer to
special steps provided separately)
Mode: II..II
Reset!
Mode: II II
Locked by abnormal oper
22
Nov. 2021
MSC-13K
bias: Z___
4
3
0
2
3
0
51time 17min
bias: Z___
4
3
0
2
3
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

167215b

Table of Contents