FAULT
POSSIBLE CASE
Column
Oil level in tank too low.
Does not
Lift
Pump drawing-in air.
Properly.
The steel plug has not been
replaced by the breather cap
Breather cap blocked.
Column
Height
Reading
Sensor zero point not
not
correct
Reach
Zero
No
Control
Fuse blown.
Power
Power switch is OFF.
Broken cable or loose
connector.
The emergency stop button
has not been unlocked.
FAULT
POSSIBLE CASE
No power supply.
No
Main fuse blown.
Power
( Power
Indicator
Main switch(es) OFF.
are Off)
REMEDY
Add oil as necessary; refer to lubricating
instructions on lifting column.
Tighten the suction filter fastening or crimp
tighter.
Install the breather cap
Clean breather cap.
Do encoder alignment
Check the fuses F1, F2 and F3. If necessary,
replace the fuse(s) in the control box. If fault
occurs again, contact the Service
Department.
Set power switch to ON.
Check cable and connector.
Release the emergency button. Set the main
switch(es) to OFF and ON.
REMEDY
Have fault corrected by qualified
electrician.
Replace fuse.
Set power switch(es) ON.
28
Nov. 2021
MSC-13K