Chapter 12. Battery Charger Informaton - IDEAL MSC-13K-B Manual

Mobile column lift set capacity 13,200lbs / each column
Table of Contents

Advertisement

12. BATTERY CHARGER INFORMATON
12.1 Technical Specifications
1.
Input voltage:
2.
Input power:
3.
Output voltage:
4.
Output current:
5.
Charge time:
6.
Size:
7.
Weight:
12.2 Panel of Charger
1. Charging indicator (
indicator on control box panel
2. Power indicator
3. Output cord
4. Power input socket
12.3 LED Performance Indicator
1. After the charged is power on, the POWER INDICATOR (2#) will be on.
2. The CHARGING INDICATOR (1#) will not on only if the battery is connected. It will
be red when battery is in fast charging.
When the battery is fully charged, it goes green.
If this CHARGING INDICATOR (1#) is flashing, the charger is in error.
100-140 VAC, 60Hz
230W ((Max)
24VDC ( Grading adaptive)
7.0A±10%
9-11 hours (battery was discharged deeply 80%)
200*150*60 mm
850g
It becomes green and red charging
)
32
Nov. 2021
MSC-13K

Advertisement

Table of Contents
loading

This manual is also suitable for:

167215b

Table of Contents