Over Current Detection Interrupt Process - Renesas RA6T2 Application Note

Sensorless vector control for permanent magnetic synchronous motor - 1shunt current detection
Hide thumbs Also See for RA6T2:
Table of Contents

Advertisement

Sensorless vector control for permanent magnetic
synchronous motor - 1shunt current detection

3.4.4 Over Current Detection Interrupt Process

The overcurrent detection interrupt is an interrupt that occurs when an external overcurrent detection signal
is input. The PWM output terminal are put in the high impedance state. Therefore, at the start of execution of
this interrupt processing, the PWM output terminal is already in the high impedance state and the output to
the motor had been stopped.
Figure 3-12 Over Current Detection Interrupt Process Flowchart
R01AN6840EJ0100 Rev.1.00
May 23, 2023
Over current detection interrupt process
Reset POEG
Set over current error
Set error status
Disable POEG interrupt
End