Vent Damper Adjustments
This fireplace is equipped
with a vent damper system
that can be adjusted using
the glass latch tool. Locate
damper adjustment rod
above the glass frame in
convection chamber at the
center. If this fireplace's vent
is terminated horizontally,
DO NOT CLOSE the vent
damper completely. Adjust
position of damper by
judging the flame
characteristics after 20
minutes of burn time. If the
flames ghost off burners or if
sooting occurs [in LPG units],
open the vent damper FULLY and work backwards in increments to determine the correct damper position for that particular
installation.
Look into the convection air cavity and note the Damper Position Indicator. Loosen damper base screw. Turn counter-clockwise
to close the vent damper, tighten screw.
If this fireplace's vent is terminated horizontally, DO NOT CLOSE the vent damper completely.

4.6 LOG SET/ MEDIA INSTALLATION

Three distinctive wood species log sets are available as options for this model Fireplace.
1. Norway Spruce Log Set
2. White Oak Log Set(not shown)
3. Birch Log Set
4. Premium Fiber Oak Log Set
Figure 4-18 Norway Spruce Logs
Installation Instructions for each log set are included with the individual log set. Follow those instructions to install one log set.
Note: Installer, save and give the copy of the Log Set Installation Instructions to the homeowner for future
references.
85-03-01113
Figure 4-17 Exhaust Damper Adjustment
Figure 4-19 Birch Logs
DXV35DT4
Figure 4-20 Premium Fiber Oak
Logs
Page 63