4.4 NATURAL GAS TO LPG CONVERSION

WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide
may result causing property damage, personal injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
A natural gas to LP gas conversion kit #HA-30-00507 must be ordered and installed in this fireplace to burn LP gas.
LP conversion kit #HA-30-00507 contains the following parts: one motorized LP pressure regulator #907.012, two cap orifices
#65-14-00364 (drill 3/64"), an L-shaped Torx wrench and an LP conversion label.
Procedure to Convert Fireplace for LP Gas
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, it is highly recommended that you
convert this fireplace and its pressure regulator, pilot natural gas/LP clip position and burner orifices prior to placing this
fireplace in its fireplace cavity.
Follow the step below to prepare this fireplace for conversion to LP gas:
1. Shut off the gas supply to the valve and shut down the electric supply.
Note: Be careful when removing or tightening the screw on the pressure regulator. Care must be taken to ensure a proper seal
when tightened. Using a ¼" Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼" minimum. Set burner aside.
4. Slide Rear Burner to the right about 2" and lift up and remove from Firebox.
5. You will now be able to access the burner orifices, which are located inside the air shutter boxes.
6. Using a ½" deep well socket wrench, remove front and rear orifices. When removing and installing the orifices be sure to use a
wrench to keep the fitting the orifice screws onto from rotating.
7. Thread a new 3/64" orifice on both the front and rear orifice mounting brass fittings. Tighten down the orifices.
85-03-01113
Figure 4-9 LP Kit Contents
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
# 907.012
Burner Orifices
#65-14-00054[54 DRILL]
2X 65-14-00364
#65-14-00055[55 DRILL]
DXV35DT4