Mendota AA-11-04152 Installation And Operating Instructions Manual page 11

Direct vent gas fireplace heater
Table of Contents

Advertisement

Mendota Fireplace Curing Instructions
It is important that the blowers are turned on during this step to prevent the curing smoke from staining the
wall finish above the fireplace. Mendota recommends completing Step 1 prior to installation of wall finish
materials.
Visible smoke and strong odor are to be expected during this step. If desired, disable smoke alarms before
this step, smoke from the initial curing cycle will set off smoke alarms. Open doors and windows of the home
to circulate fresh air.
Step 1: Expelling Initial Smoke and Odors
Please refer to
Chapter 5.8 Operating
Complete the installation of any barrier screen (required), surround, front or doors.
Turn the fireplace on in the Manual (Off) thermostat mode.
Set the Flame Height to Hi.
Set the Fan Speed Control to Level 3.
Run the fireplace with these settings for a minimum of 2 hours.
Turn the fireplace off and let it cool.
Step 2: High Heat Curing Cycle
Turn the fireplace on in the Manual (Off) thermostat mode.
Set the Flame Height to Hi.
Set the Fan Speed Control to Off.
Run the fireplace with these settings until curing odors have diminished.
When odors have diminished leave the fireplace turned on and continue to Step 3.
Step 3: Final Curing Cycle
With the fireplace still turned on from Step 2.
Set the Fan Speed Control to the lowest setting Level 1.
If any new curing odors are detected, continue to run the fireplace with this setting until the curing odors have
diminished.
ATTENTION: Slight odors may still be noticeable on future startups of the fireplace. These will diminish over time as the
fireplace is used.
Additional Curing Information
It is not unusual for a fireplace to require more than 10 continuous hours on high for curing odors to diminish. There are
variables that can extend or shorten the curing time such as decorative fronts, doors, facing materials and their application.
Finish materials around the fireplace are subject to high temperatures. Finishing materials used over the fireplace in the non-
combustible zone can see temperatures around 350° F. Materials used around the fireplace must be rated for these
temperatures. Failure to use adequate materials can result in odor problems. Please refer to
information on appropriate finishing materials.
Please be aware that materials used around the fireplace will heat up and have the potential to cause odor issues. Adhesives,
glue, wall substrate, wall finish material, paints and polishes are common materials that if used incorrectly will cause odor
issues. Mendota is not responsible for any odor issues caused by materials used around the fireplace.
85-03-01113
ATTENTION
Instructions, if you have questions on how to operate your Mendota.
DXV35DT4
of this manual for
Chapter 3.2.4.3
Page 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv35dt4

Table of Contents