Direct vent gas fireplace heater
Table of Contents

Advertisement

Fireplace Features
EXTERNAL DIMENSIONS: 36-1/4 Wide X 31-7/16" High X 15-5/8" Deep
MINIMUM FRAMING DIMENSIONS: 36-1/4" WIDE x 31-7/16" HIGH X 15-1/8" DEEP
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 28-3/8" X 16-1/16".
MANTEL ALLOWANCE: 8" Deep Mantel at 14" Above Top Convection Opening (41" up from base of Unit)
VENT SYSTEM ALLOWANCE: Top Vent Only. 12" Vertical Minimum with 6" max horizontal. 55 feet Vertical Maximum. 4"
exhaust and 6-5/8" combustion air intake coaxial vent pipe required. 12' maximum horizontal run allowed with 4' minimum
vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE: There is one exhaust vent damper included in this unit and located in the top
convection chamber at the center.
CONTROLS: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blowers operate on AC
Power only. Thermostatic Remote-Control Transmitter with Smart Thermostat Mode.
BLOWER SYSTEM: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
Accent Light System: Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted behind
lower grill. Accent Light can also be turned on or off using Remote Control Transmitter.
BURNER SYSTEM: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air shutter.
LOG SET: 9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5"WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #44.
LPG INFORMATION: LP conversion kit #HA-30-00507 is required. 12"WC Minimum inlet pressure required. For the DXV35 DT4
LPG application, both front are rear burner orifices are to be drill size 3/64". For higher altitude, adjustment to orifice size may
be necessary.