Mendota AA-11-02592 Installation And Operating Instruction Manual

Mendota AA-11-02592 Installation And Operating Instruction Manual

Fullview linear direct vent gas fireplace heater
Table of Contents

Advertisement

Quick Links

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour consulta-
tion ultérieure.
1 |
P a g e
FULLVIEW LINEAR DIRECT VENT GAS FIREPLACE HEATER
Flush-Faced Model ML47-PF2, AA-11-02592
INSTALLATION and OPERATING INSTRUCTIONS MANUAL
DOCUMENT NO. ML47-PF2-IM-1216
AVERTISSEMENT : Assurez-vous de bien suivre les in-
structions donné dans cette notice pour réduire au minimum
le risque d'incendie ou pour éviter tout dommage matéeriel,
toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vape-
rurs ou liquides inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appe-
lez le service dos incendies.
L'installation et service doit être exécuté par un
installer, agence de service ou le fournisseur de gaz.
DE
qualifié

Advertisement

Table of Contents
loading

Summary of Contents for Mendota AA-11-02592

  • Page 1 FULLVIEW LINEAR DIRECT VENT GAS FIREPLACE HEATER Flush-Faced Model ML47-PF2, AA-11-02592 INSTALLATION and OPERATING INSTRUCTIONS MANUAL DOCUMENT NO. ML47-PF2-IM-1216 WARNING: If the information in this manual is not AVERTISSEMENT : Assurez-vous de bien suivre les in- structions donné dans cette notice pour réduire au minimum followed exactly, a fire or explosion may result le risque d’incendie ou pour éviter tout dommage matéeriel,...
  • Page 2: Safety And Warning Information

    WARNING Cet appareil peut être installé dans un maison préfab- Mendota gas fireplaces are heat producing appliances. riquée (mobile) déjà installée à demeure si les règle- Do not burn wood, paper or other materials in this fire- ments locaux le permettent.
  • Page 3 Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
  • Page 4: Table Of Contents

    Table of Contents SAFETY AND WARNING INFORMATION ......................2 SPECIFIC REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS ........6 ML47 FULL VIEW GAS FIREPLACE DIMENSIONS ................... 7 ML47 FEATURES - QUICK REFERENCE INFORMATION ................8 TECHNICAL SPECIFICATIONS FOR ML47 LINEAR ZC DECORATIVE FIREPLACE ........9 CONGRATULATIONS ............................
  • Page 5 ML47 GAS IGNITION SYSTEM WIRING DIAGRAM ..................62 GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT ................63 LISTING LABEL INFORMATION ........................64 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ..........67 MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY ............... 69 P a g e...
  • Page 6: Specific Requirements For The Common Wealth Of Massachusetts

    Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common Wealth of Massachusetts only. For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than seven (7) feet above grade, the following requirements shall be satisfied: If there is no carbon monoxide detector with an alarm already installed in compliance with the most current edition...
  • Page 7: Ml47 Full View Gas Fireplace Dimensions

    ML47 FULL VIEW GAS FIREPLACE DIMENSIONS OVERALL APPLIANCE DIMENSIONS AND FEATURES Lower Cover Plate Upper Cover Plate Removable Cover Plate for Plumbing & Electrical Access before unit is placed inside framed cavity. Replace Lower Cover Plate before sliding unit into framed cavity.
  • Page 8: Ml47 Features - Quick Reference Information

    ML47 FEATURES - QUICK REFERENCE INFORMATION CERTIFICATION and LISTING: Certified under ANSI Z21.88 (2014) • CSA 2.23 (2014) “Vented Gas Fireplace Heater " not for use with solid fuel. Not to be used as primary heat source. EFFICIENCY RATINGS: P.4 Fireplace Efficiency 71.3%. AFUE Natural Gas 70%, AFUE LP Gas 70.7% EXTERNAL DIMENSIONS: 54-1/4”...
  • Page 9: Technical Specifications For Ml47 Linear Zc Decorative Fireplace

    TECHNICAL SPECIFICATIONS FOR ML47 LINEAR ZC DECORATIVE FIREPLACE MODEL ML47 High Fire - Adjustable to - Low Fire BTUH. (MODEL ML47) NAT. GAS 41,000 25,000 BTUH. (MODEL ML47) LP GAS 41,000 24,000 NOTE: LPG CONVERSION KIT, #HA-90-00110 MUST BE PURCHASED SEPARATELY TO CONVERT TO BURN LPG IN THIS FIREPLACE.
  • Page 10: Congratulations

    Fireplace and replace any part of the control system and any gas control, which has been under water. DO NOT use this fireplace if the burner does not light immediately. Turn unit off and call Mendota ap- proved service person if there is any delay in burner light off.
  • Page 11: General Appliance Specifications

    ML47-M DIRECT VENT GAS FIREPLACE GENERAL APPLIANCE SPECIFICATIONS HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. 44-3/4 63-5/16 23-5/8 23-5/8 63-5/16 89-9/16...
  • Page 12: Mantel Clearances

    MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For ease, however, measure up from the floor level of this fireplace.
  • Page 13: Clearance To Side Wall Projections

    CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 1: Clearances to Combustibles 0" CLEARANCE FROM TOP STANDOFFS 1/2" CLEARANCE FROM BACK 1/2" CLEARANCE FROM SIDES CLEARANCE TO SIDE WALL PROJECTIONS Any side wall adjacent to Left or Right side of this appliance protruding out more 16" in from of the front surface of the visi- ble glass door and if perpendicular to the front surface of the glass door must be located a minimum of 16"...
  • Page 14: Planning The Installation

    PLANNING THE INSTALLATION When planning on appliance installation, it is necessary to determine the following information before installing: • Where the appliance is to be installed. • The vent system configuration to be used. • Gas supply piping. • Electrical Wiring. •...
  • Page 15: Rough Framing Dimensions

    ROUGH FRAMING DIMENSIONS Rough Framing Dimensions The Rough Framing Dimensions must be main- Minimum Rough Framing Dimensions tained to allow this fireplace to slide into the DESCRIPTION DIMENSION (INCHES) framing cavity. Width 54-1/4 If the fireplace is to be recessed in a cavity Height 39”...
  • Page 16: Framing Depth And Finishing Guides

    2” thick or if you wish the Grace Decorative Front to be recessed closer to the viewing glass surface. If Outer Guides are required, order part number HA-90-00030 from your Mendota Dealer.
  • Page 17: Adjustable Framing Brackets

    Install 1/2'” thick drywall on framing members so that its outer surface is flush with the front face of this fireplace. Attach Marble or Granite slabs to face of unit and to drywall surface using adhesive that does not off gas when hot. Mendota rec- ommends the use of Copper RTV Silicone as the adhesive applied in thin 1/8 beads of spline shapes.
  • Page 18: Decorative Fronts Information

    Decorative Fronts Information: No Front: The ML47 Fireplace can be installed without a decorative front. If the Fireplace is installed without a decorative front ML47 Safety Barrier Part#: AA-11-01100 must be installed on the Fireplace before operation. Traditions Front Only: The Traditions Front is approximately the overall size of the viewing glass frame. This Front mounts using steel barrel nuts on the outer sides of the viewing glass frame.
  • Page 19 Grace Front Only: The Grace Front’s inner edges start outside the convection air gaps around the viewing glass frame. This Front is mounted using steel spacers and screws on the outer sides of the convection air gap on the sides of the viewing glass frame.
  • Page 20: Non-Combustible Finishing Materials Requirements

    Final Finishing Material mounted behind the Grace Front, using the Inner Guides: If the Final Finishing Material is mounted behind the Grace Front and you wish the front visible faces of the Grace Front and the Traditions or Willowbrook to be close to each other, you have one option: 1.
  • Page 21: Raised Height Installation Of Ml47

    RAISED HEIGHT INSTALLATION OF ML47 The ML47 Linear Gas Fireplace may be installed in an elevated configuration. Please consult the table, below to deter- mine the maximum raised height allowable based on the internal ceiling height of the room this Fireplace is installed in. MAXIMUM MAXIMUM Room Ceil-...
  • Page 22: How To Determine The Proper Installed Height Of This Fireplace

    The bottom edge of the visible glass will be located 9-3/16” up from the floor level in this configuration. Mendota recommends that the ML47 be installed on an elevated wood framed support stand of at least 15” tall which will result in the bottom edge of the visible glass locating at 24”...
  • Page 23: Installation Of Flat Panel Tv On Top Of Ml47

    Follow the specific framing dimen- sion and instructions provided below. Men- dota does not warrant any TV installed above a Mendota Fireplace against heat damage. Given, below, is the minimum TV Cavity framing and creation method. If possible,...
  • Page 24: Enamel Panoramic Liner And Floor Plate Installation Requirement

    ENAMEL PANORAMIC LINER AND FLOOR PLATE INSTALLATION REQUIREMENT There exist 5 color options for the required Panoramic Panel Kit. The Panoramic Panel and a matching floor plate are available in Black, Midnight Black, Copper, Mocha Metallic and Silver Metallic attractive colors. You must select one col- ored Panoramic Panel Kit and install it before any test firing of this appliance.
  • Page 25: Backup Dc Power Inlet Port Installation

    BACKUP DC POWER INLET PORT INSTALLATION Under normal conditions when AC power is available, this appliance is designed to operate on 110 VAC power. During power outages, it is designed to operate using 6 V DC backup power. This appliance is supplied with a DC power inlet harness, a single gang outlet box and two single cover plates.
  • Page 26: General Information

    Simpson DuraVent pipe components and all adjustable pipe sections. The Mendota Direct Vent Fireplace may be placed within 16 inches of adjacent sidewalls. The fireplace may be placed directly on concrete or wood flooring. If the appliance is to be installed on carpeting, vinyl or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel placed on top of the flooring material and extending the full width and depth of the appliance.
  • Page 27: Gas Supply Requirements

    GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when in- stalling the fireplace.
  • Page 28 regulator is of adequate capacity to service the gas appliances (such as dryer, furnace, etc.). If this regulator's capacity is not sufficient to add the Gas Fireplace, an additional "inches to inches" regulator must be installed for the Fireplace. EXCEPTION: Some codes allow 2-PSI (1.4KPA) supplies to enter the residence, in which case "pounds to inches" regula- tors are used.
  • Page 29: Gas Input Rate Verication Requirements

    GAS INPUT RATE VERICATION REQUIREMENTS Natural Gas Applications Gas Input Rate Verification Procedures Verify Main Orifice Size. The main orifice body has the orifice hole size stamped on it. NG orifice size shall be 1/8" for 0-2000 feet elevation and #31 for elevations exceeding 2000 feet. Verify that the Manifold Gas Pressure is within 3.5"...
  • Page 30: General Installation Instructions

    The ML47-PF2 Fireplace must be installed by a qualified service person. CAUTION: The Mendota ML47 Fireplace may be installed in a manufactured (mobile) home after the first sale of the home. Manufactured home (mobile home) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A, or CSA Z240.4-Gas Equipped Mobile Housing.
  • Page 31: General Flue Venting Instructions

    Common vent systems are prohibited. To assure proper venting performance of this high-performance Mendota Direct Vent Fireplace, it is critical that all brands of vent pipe sections are sealed tightly and leak-proof. This means that all pipe sections must be carefully rotated into the fully "twist-locked"...
  • Page 32: Exterior Vent Locations And Restrictions

    EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 7: Exterior Vent ALL MEASUREMENTS FROM CENTER-LINE OF VENT CAP Ú - Ù - º - Vent Terminal Air Supply Inlet Area where terminal is not permitted Clearance above grade, veranda, porch, *Not to be installed above a meter/regulator as- deck, or balcony (*12 inches (30 cm) mini- sembly within 3 feet (90 cm) horizontally from mum).
  • Page 33: Flue Venting Components Identification

    DO NOT SEPARATE TELESCOPING SECTIONS. USE TELESCOPING SECTIONS AS COMPLETE ASSEMBLIES. HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. ITEM DESCRIPTION 6" or 7” PIPE (DuraVent 6”/Amerivent 7”) 12"...
  • Page 34: Ml47 Master Flue Venting Requirements Chart

    4 feet or longer. Figure 9: NATURAL GAS CHART HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. Natural Gas ONLY V min H max 18 in.
  • Page 35: Important Venting Configuration Notes

    USING 90 ELBOWS IN ZONE “B” The ML47 Fireplace by MENDOTA allows maximum flexibility in the use of 90 elbows in the vent system. The length of the first straight vertical section directly connected to the fireplace’s starter collar determines the maximum horizontal run and the number of 90 elbows allowed for this fireplace.
  • Page 36: Approved Vent Systems

    APPROVED VENT SYSTEMS Figure 10: Vent Systems QUICK REFERENCE CHART STRAIGHT UP, VERTICAL VENTING ZERO VERTICAL HORIZONTAL TERMINATION VERTICAL RISE HORIZONTAL TERMINATION 40 FEET MAXIMUM NOT ALLOWED APPROVED APPROVED VERTICAL RISE DUAL 90° ELBOWS HORIZONTAL TERMINATION VERTICAL RISE DUAL 90° ELBOWS VERTICAL TERMINATION ZERO VERTICAL DUAL 90°...
  • Page 37: Zero Rise Horizontal Termination

    ZERO RISE HORIZONTAL TERMINATION The ML47 Fireplace must be installed by a qualified Mendota approved serviceperson. When the minimum 18” vertical and following 90-degree elbow is connected directly to this fireplace, the horizontal center- line of the 90ºelbow will be 53” inches up from the floor level of this Fireplace.
  • Page 38: Vertical Rise Horizontal Termination

    This will cause high temperatures and the possibility of a fire. This ML47 Fireplace must be installed by a qualified Mendota service person Position fireplace in desired location. See Figure 13 for guidelines on proper vent cap placement on exterior of home.
  • Page 39 Figure 14 V min H1 +H2 max 24 in. 2 ft. 30 in. 9 ft. 36 in. 15 ft. 42 in. 21-1/2 ft. 48 in. 28 ft. 4 ft. - 10 ft. 28 ft. 10 ft. - 40 ft. Varies Figure 15 V2 max H2 max...
  • Page 40: Vertical Through-The Roof Venting

    Doing so will continue to allow the use of the 40 feet maximum vertical run. The ML47 Fireplace must be installed by a qualified Mendota approved serviceperson. 1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit.
  • Page 41 Figure 17 Figure 16 V2 max V1 min H max 38-1/2 ft. 18 in. 6 in. 34 ft. 24 in. 6 ft. 27 ft. 30 in. 13 ft. 21 ft. 36 in. 19 ft. 14-1/2 ft. 42 in. 25-1/2 ft. 10 ft.
  • Page 42: Vertical Through-The-Roof Venting Using Four 90

    Mendota has spent considerable time and effort in the design of this fireplace and its venting system. Through this effort, Mendota has been able to certify the use of Four 90 elbows.
  • Page 43: Ml47 Door Operation

    ML47 DOOR OPERATION TO REMOVE DOOR Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into hole in latch, pull towards you and Rotate 90 degrees to disengage top latches. Remove tool. There are two spring latches on top of this gas fireplace.
  • Page 44: Installation Check Off List

    The following Check-Off Lists must be completed prior to final operation of the Fireplace. INSTALLATION CHECK OFF LIST Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in accordance with instructions. All joints must be secured, "twist- locked"...
  • Page 45: Ml47 Burner Media Installation Instructions

    Many media choices are available directly from Mendota for use on the ML47 model. Select one media and purchase sep- arately. Specific installation instructions are included with the Driftwood and Twig Set options.
  • Page 46: Location Of Master Switch And Sync Switch

    LOCATION OF MASTER SWITCH AND SYNC SWITCH The Master Switch and Sync Switch are located 9-3/4” to right from the left edge of the glass frame and under the bottom edge of the glass frame in the bottom air gap. Use the glass latch tool to actuate the two switches.
  • Page 47: Remote Control Transmitter Functions

    BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Fail- ure to follow the instructions may result in property damage, bodily injury, or even death. Remote Control Transmitter Functions NOTE: The Wall Receiver will “beep”...
  • Page 48: Remote Transmitter Operating Instructions

    Once you set the desired fan control, the system will re- member your selected fan speed until you manually change it. Accent-Light Dimmer: This function controls the Mendota Accent Light functions. Pressing the UP key in this mode will TURN ON the Accent Light and allow you to control the brightness of the Accent Light in 6 steps.
  • Page 49 TEMPERATURE INDICATOR ( F or Press the ON/OFF Key and Turn Off the Fireplace. Simultaneously, Press both the MODE Key and the Thermostat Key. Look at the LCD display to verify that your desired indicator ( F or C) is being displayed. If not, repeat step 2. KEY LOCK FUNCTION To prevent unsupervised children from operating the fireplace, a KEY LOCK function is pro- vided with this remote control system.
  • Page 50: First Time" Pilot Lighting Instructions

    “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the Master On/Off switch is toggled to the ON position.
  • Page 51: Ipi/Standing Pilot System Information

    “IPI” mode. One set to the desired setting, press On/Off button to activate the fire- place. NOTE: Mendota Fireplaces recommends that the (CPI) Standing Pilot Mode be used during the win- ter months when the average daily high temperature falls below 50 F.
  • Page 52: Trouble Shooting The Ml47 Fireplace & Maintenance Information

    Mendota dealer promptly informed. Mendota dealers will correct "sooting" problems, but Mendota and their dealers are not responsible for damage caused by excessive sooting that has not been immediately brought to their attention.
  • Page 53: Maintenance

    MAINTENANCE ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or burner media 1" MIN. 1" MIN. must be done by a qualified Mendota service person.
  • Page 54: Basic Maintenance

    BASIC MAINTENANCE To access internal components for general service or maintenance requirements, remove any decorative front, remove the glass door, remove all burner media, inner Panoramic Lining and floor plate, remove main burner. Locate two access plates on the left and right side of firebox floor.
  • Page 55: Natural To Lp Gas Conversion

    NATURAL TO LP GAS CONVERSION Kit # HA-90-00110 for Mendota Model ML47 This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, per- sonal injury or loss of life.
  • Page 56 WARNING: It is of the utmost importance that the correct burner orifice be installed Turn off gas supply at the appliance service valve. See written instructions that accompany the LP pressure regulator. 1. Using a Torx T20 or a slotted screwdriver, remove 2 screws that secure the NG Pressure Regulator to the gas valve body and remove NG Pressure Regulator, see following page.
  • Page 57: Lp Pressure Regulator Conversion Instructions

    LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically ap- proved with this appliance may result in property damage or personal injury.” AVERTISSEMENT. Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à...
  • Page 58: Lp Gas Pressure Requirements

    LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct gas pressures during the LP Kit installation and before fascia materials are installed over the front of this fireplace.
  • Page 59 1" MIN. 1" MIN. 59 | P a g e...
  • Page 60: Checking For Normal Burner (S) Ignition Characteristics

    CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS Once the conversion to LPG and all the above steps have been completed, install Burner Media and light the main burner. On the Remote Transmitter, push On/Off button to ON . Change Thermostat Mode to "MANUAL". The pilot system will begin to spark and then the Main burner should light and flame should not "lift"...
  • Page 61: Ml47 Valve Assembly Replacement Parts

    ML47 VALVE ASSEMBLY REPLACEMENT PARTS ML47 VALVE ASSEMBLY REPLACEMENT PARTS LIST PART ITEM NUMBER DESCRIPTION 05-04-00062 Pilot Assembly 65-14-00180 ORIFICE, 1/8” HA-90-00004 Proflame Valve Assembly with fittings 55-02-00070 TUBING, 3/8" OD X 12 SS 304 Figure 20: ML47 VALVE ASSEMBLY 61 | P a g e...
  • Page 62: Ml47 Gas Ignition System Wiring Diagram

    ML47 GAS IGNITION SYSTEM WIRING DIAGRAM Optional Fan Kit The appliance must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current NFPA 70-National Electric Code or CSA C22.1-Canadian Electrical Code. Caution: Label all wires prior to disconnection when servicing controls.
  • Page 63: Glass Frame Assembly Repair And Replacement

    GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT GASKET DO NOT substitute other manufac- WARNING turer's materials or components. WARNING Do not operate this appli- DO NOT operate unit with cracked, Use only authorized parts and ance with the glass re- broken or missing glass. materials obtained from Johnson moved, cracked or broken.
  • Page 64: Listing Label Information

    LISTING LABEL INFORMATION The model information regarding your specific appliance can be found on the rating plate, which is located in the air gap below the glass frame near the center. When contacting your dealer for any cleaning service or warranty service, always provide the Model Number, Serial Number and Manufactured Date.
  • Page 65 THIS PAGE LEFT BLANK, INTENTIONALLY. 65 | P a g e...
  • Page 66 THIS PAGE LEFT BLANK, INTENTIONALLY. 66 | P a g e...
  • Page 67: Mendota Warranty Qualification & Service Reference Form

    As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration to Mendota.
  • Page 68 TAPE SHUT POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W. CEDAR RAPIDS, IA 52405 68 | P a g e...
  • Page 69: Mendota Extended Protection And Limited Warranty

    YEARS TO THE ORIGINAL OWNER. SUBJECT TO PROOF OF PURCHASE AND THE CONDITIONS AND LIMITATIONS OUTLINED, BELOW. This new Mendota Fireplace must be installed & serviced by a competent, authorized service contractor. It must be installed and operated at all times in accordance with the installation and operating instructions furnished with the Fireplace.
  • Page 70 Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com www.mendotahearth.com 85-03-00923 70 | P a g e...

This manual is also suitable for:

Ml47-pf2

Table of Contents