Burner And Pilot System - kozy heat CHASKA 29 GLASS Installation And Operation Manual

Direct vent gas fireplace insert
Hide thumbs Also See for CHASKA 29 GLASS:
Table of Contents

Advertisement

14.5 Burner and Pilot System

The burner assembly may be removed for easier access to the control
compartment. See 9.4 Control Board Removal and Installation on
page 29.
Verify gas supply is turned on and filled. Consult with plumber or gas
supplier as necessary.
Qualified Service Person
Performed by:
Annually
Frequency:
Action:
Vacuum all components of the burner system.
Check all accessible gas-carrying tubes, connections, pipes and
other components for leaks.
Inspect the operation of the flame safety system Pilot or Flame
rectification device. Visually check pilot light when in operation.
Inspect and ensure the lighting of the main burner occurs within
(4) seconds of the main gas valve opening. Check for faulty or
incorrect wiring and correct or replace as necessary. Inspect
primary air openings (burner ports) for blockage, especially near
the pilot.
Visually check burner flame pattern when in operation. Flames
should be steady, not lifting or floating.
Test and measure the flame failure response time of the flame
safety system. It must de-energize the safety shutoff in no more
than (30) seconds.
Burner ori ce
BURNER PORTS
Figure 14.1, Burner System
42 MAINTENANCE
Figure 14.2, Pilot and Burner Correct Flame Appearance
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Ideal Flame Appearance
Lazy, yellow ames - no adjustment necessary
#CSK-29-G R.9 August 2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csk-29-g

Table of Contents