Optex CX-702S Installation Instructions
Optex CX-702S Installation Instructions

Optex CX-702S Installation Instructions

Passive infrared detector

Advertisement

Quick Links

8
TROUBLE SHOOTING
CX-702RS
PROBLEM
PROBLEM CAUSE
Detection area is improper.
Transmitter is not connected to PIR.
Wireless transmitter has not arrived at a receiver.
Alarm is not activated although
Battery is dead.
someone is walking in the
Walk test switch is OFF.
detection area.
Polarity of the detector is improper.
Power supply voltage is improper. (disconnection or low voltage)
Alarm condition when no alarm is
Moving object within detection area. (curtain, wall hanging, etc.)
activated although nobody is in
Temperature of object within area is changing rapidly.
the area.
(heater, air conditioning, etc.)
Walk test switch is OFF.
LED does not light up
at the time of walk test.
Battery is dead.
CX-702S
PROBLEM CAUSE
PROBLEM
Power supply voltage is improper. (disconnection or low voltage)
Detection area is improper.
LED does not light.
LED switch is OFF.
Polarity of the detector is improper.
LED lights even though no person
Moving object within detection area.(curtain, wall hanging, etc.)
within area.
Temperature of object within area is changing rapidly.
(heater, air conditioning, etc.)
LED lights but
Relay contact is stuck or damaged due to overloading.
signal is not sent.
9
MAINTENANCE
Conduct a walk test at least once a year to confirm proper operation.
When using CX-702RS and a transmitter in common, the battery life
will be shortened depending on the transmitter type (current draw).
The assumption battery life is shown bellow. The battery life will
change depending on the temperature.
Approx. 3 years/
9 V Alkaline battery (560 mAH)
Battery life
Approx. 7 years/ 3.6 V Lithium battery
(850 mAH)
(CX-702RS only)
Approx. 10 years/
9 V Lithium battery (1,200 mAH)
Dimensions
100 (3.94)
mm (inch)
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
https://navi.optex.net/cert/contact/
(The Netherlands)
www.optex-europe.com/nl
REMEDY
Conduct a walk test. See section 2 and 7-3.
See section 5.
Check the transmitter.
Change battery.
Turn the walk test switch ON. See section 7-3.
Replace the polarity of a terminal. See section 5.
Check the wiring is correct or not. Or there is not
a battery in the detector.
Remove the object from the detection area.
Remove the heat sources from the detection area
or relocate the detector.
Turn the walk test switch ON.
Change the battery.
REMEDY
Correct supply voltage to 9.5 - 16 V DC. See section 5.
See section 5.
Turn ON the switch. See section 7-1.
Switch positive and negative at terminal. See section 5.
Remove the heat sources from the detection area.
Remove the object from the detection area.
Check load of output. The unit needs repair or
replacement.
10
SPECIFICATIONS
Model
CX-702RS
Detection method
Passive infrared
Coverage/
Wide angle 85° 21 m x 21 m (70 ft. x 70 ft.)/ 68 zones
Detection zones
Long range 45 m x 2.4 m (150 ft. x 8 ft.)/ 22 zones
Mounting height
1.5 to 3.6 m (5 to 12 ft.)
1.6℃ at 0.6 m/s 2.4 m mounting height
Sensitivity
(3℉ at ft./s 8 ft. mounting height)
Detectable speed
0.3 to 1.5 m/s (1 to 5 ft./s)
Alarm period
Approx. 2.5 s
Pulse count
Approx. 20 s, 2 or 4
3 to 9 V DC
Power input
9.5 to 16 V DC
Alkaline or Lithium battery
(Operation Voltage)
(2.3 to 10 V DC)
Normal
5 µA (stand-by)
15 mA
Current draw
Max.
10 mA
20 mA at 12 V DC
(Walk test, LED ON) at 9 V DC
Form C-solidstate switch
Alarm output
10 V DC, 0.01 A max.
15 V DC, 0.2 A max.
Tamper switch
Form C
Warm-up period
Approx. 90 s
Approx. 60 s
Alarm condition
Disable during normal operation
LED indicator
Alarm indicator optional (walk test)
RF interference
No alarm 20 V/m
No alarm 30 V/m
Operation temperature
-10℃ to +50℃ (+14℉ to +122℉)
-20℃ to +50℃ (-4℉ to +122℉)
Environment humidity
95% max.
Weight
200 g (7.0 oz.)
* Specifications and design are subject to change without prior notice.
Note>>
• This unit is designed to detect movement of an intruder and activate an
alarm control panel.
• Being only a part of a complete system, we cannot accept responsibility
for any damages or other consequences resulting from an intrusion.
OPTEX CO., LTD. (JAPAN)
www.optex.net
OPTEX SECURITY SAS (France)
OPTEX KOREA CO.,LTD. (Korea)
www.optex-europe.com/fr
www.optexkorea.com
OPTEX SECURITY Sp.z o.o. (Poland)
OPTEX (DONGGUAN) CO.,LTD.
www.optex-europe.com/pl
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
OPTEX (Thailand) CO., LTD. (Thailand)
www.optexpinnacle.com
www.optex.co.th
Copyright (C) 2016-2021 OPTEX CO.,LTD.
4
PASSIVE INFRARED DETECTOR
PASSIVE INFRARED DETECTOR
CX-702RS , CX-702S
CX-702RS , CX-702S
Battery operated (CE)
FEATURES
- Selectable "WIDE ANGLE" and "LONG RANGE" detection patterns
- Double conductive shielding of the pyroelectric element, extremely high light
- Multifocus optics design (Patent listed)
- Sealed optics
- Easy installation
OPTIONS
- CA-1W: Wall mount bracket/ CA-2C: Ceiling mount bracket;
Adjustable ±45˚(Horizontally), 0 to 20˚(Vertically downwards)
- BA-70: Backbox for wireless transmitter
1
INSTALLATION HINTS
1
CX-702S
Avoid direct sunlight.
5
Do not install outdoors.
2
DETECTION AREA
W
D I
E
A
N
G
L
E
Form C
TOP VIEW
-
0
10
20
30
40
30
20
10
0
10
20
ft.
30
0
5
10
SIDE VIEW
0
10
20
30
40
A
5
ft.
8
0
5
10
0
10
20
30
40
B
5
8
ft.
12
0
5
1
0
0
10
20
30
40
5
8
C
ft.
12
0
5
10
Form C Relay
2
3
Avoid mounting detector where
movement of Fans or Air
Avoid vapor or high
humidity that can
Conditioning Fans can be
detected.
cause condensation.
6
7
WARNING
When damage has occurred to
WARNING
the product, i.e. water logged,
Never repair or modify
abnormal things inside product,
product. It may cause
overheating or smoking, strange
accident, fire hazard or
smells etc., immediately stop
electric shock.
using product and contact your
supplier. Otherwise, continued
use in such condition may cause
electric shock or fire hazard.
L
O
N
G
R
A
N
50
60
70 ft.
0
10
20
30
40
50
10
5
0
ft.
5
5
0
5
10
15
0
0
10
20
30
40
50
5
A
5
ft.
8
0
5
10
15
10 m
15
20 21 m
0
10
20
30
40
50
50
60
70 ft.
B
5
8
ft.
12
1.5
2.4 m
0
5
10
15
15
20 21
m
0 0
10
20
30
40
50
50
60
70 ft.
C
5
1.5
8
2.4
ft.
12
3.6 m
0
5
10
15
1
5
2
0
2
1
m
50
60
70 ft.
**ATTENTION**
The specified detection area can be achieved by mounting the unit at a height of 2.4 m (8 ft.).
1.5
Mounting at a lower or higher height may reduce the area of coverage
2.4
3.6 m
1
15
20 21
m
No.59-0974-5 2111-26
INSTALLATION INSTRUCTIONS
EN
CX-702RS only
- Low current draw: 5µA (Normal in standby)
- Battery operated
- Form C alarm output and tamper switch
CX-702S only
- Form C alarm output relay
- LED ON/OFF switch
4
Avoid Curtain,Screen,etc.
blocking detection area.
8
CAUTION
Mount securely.
A falling product
may cause injury.
This symbol indicates prohibition.
G
E
TOP VIEW
60
70
80
90
100
110
120
130
140
150 ft.
2
1
0
1
2
m
20
25
30
35
40
45
m
SIDE VIEW
60
70
80
90
100
110
120
130
140
150 ft.
1.5
2.4 m
20
25
30
35
40
45
m
60
70
80
90
100
110
120
130
140
150 ft.
1.5
2.4
3.6 m
20
25
30
35
40
45
m
60
70
80
90
100
110
120
130
140
150 ft.
1.5
2.4
3.6 m
20
25
30
35
40
45
m

Advertisement

loading

Summary of Contents for Optex CX-702S

  • Page 1 OPTEX INC./AMERICAS HQ (U.S.) OPTEX SECURITY SAS (France) OPTEX KOREA CO.,LTD. (Korea) 150 ft. 70 ft. www.optexamerica.com www.optex-europe.com/fr www.optexkorea.com OPTEX (EUROPE) LTD./EMEA HQ (U.K.) OPTEX SECURITY Sp.z o.o. (Poland) OPTEX (DONGGUAN) CO.,LTD. www.optex-europe.com www.optex-europe.com/pl SHANGHAI OFFICE (China) 3.6 m 3.6 m www.optexchina.com...
  • Page 2 Select wide angle or long range according Fit cover using fastening screw. to Section 6-2. (Note:Factory default is WIDE ANGLE.) LED ON / OFF ( CX-702S Only ) Jumper Pin Switch Guides of Lens Holder The Alarm LED indicator can be switched either “ON” or “OFF”.

This manual is also suitable for:

Cx-702rs