7.TROUBLE SHOOTING
PROBLEM
PROBABLE CAUSE
Improper power supply voltage.
(disconnection,low voltage)
RED LED does not light.
Improper detection area.
LED switch is OFF.
Improper polarity to detector.
Moving object within area. (curtain, wall hanging, etc.)
RED LED lights even
though no person
Temperature of object within area changing rapidly
within area.
(heater, air conditioning, etc.)
Relay contact is stuck or damaged due to overloading.
RED LED lights but
signal is not sent.
Faulty wiring.
Red LED does not stop
Insufficient power supply.
flickering (warm-up)
Detector is masked.
Yellow LED flickers
(CX-502AM only)
Strong light, electrical noise cause anti-masking
false alarm.
Incorrect initialization.
Red and Yellow LED does
not stop flickering.(warm-up)
Insufficient power supply.
8.SPECIFICATIONS
CX-502
Model
Passive infrared
Detection method
Wide angle 85° wide
Coverage
50ft x 50ft
(15m x 15m)
Detection zones
82 zones
Mounting height
6 ~ 10ft(1.8 ~ 3.0m)
Sensitivity
3° F (1.6° C) at 2ft / sec (0.6m/sec)
1~ 5ft / sec (0.3 ~ 1.5m/sec)
Detectable speed
9 ~ 18VDC
Power input
5mA (normal)
/ 12mA (max.)
Current draw
Alarm period
2.0 ± 0.5sec
Alarm output
N.C. 28VDC 0.2A max.
Tamper switch
N.C. Opens when cover is removed.
Warm-up period
Approx. 1 min.(LED blinks)
LED is blinking during warm-up period.
LED indicator
Alarm condition
D.L.terminal ((BE) Only)
See Section6-2
RF interference
No alarm 30V/m
Operating temperature
-4°F ~ +122°F(-20°C ~ +50°C)
Environment humidity
95% max.
Weight
4.2oz (120g)
Model
CX-502V
Current draw
5mA(normal) / 13mA(max.)
Alarm Memory
See Section6-4
D.L.terminal
See Section6-2
Weight
4.2oz(120g)
CL-80N ( Optional lens for long range curtain pattern )
Coverage
80ft x 7.7ft
(24m x 2.3m)
Detection zones
22 zones
*Specifications and design are subject to change without prior notice.
NOTE
This unit is designed to detect movement of an intruder and activate an
alarm control panel.
Being only part of a complete alarm system,we cannot accept
responsibility for any damages or other consequences resulting from an
intrusion.
This product confirms to the EMC Directive 89/336 EEC.
No.0881 0001-11
59-0881-1
00-03
REMEDY
Correct supply voltage to 9~18V DC.
[See Section 2~4].
Turn on the switch.
Switch positive and negative at terminal.
Remove the souces from the detection area.
Remove object from detection area.
Check load of output.
The unit needs repair or replacement.
Wire correctly.
Correct supply voltage to 9~18V DC.
Remove masking material and continuous double
flickering of Red LED stops after several seconds.
Remove such causes.
Initialize correctly according to [Section 6-6].
Correct supply voltage to 9~18V DC.
Model
CX-502AM
7mA(normal) / 19mA(max.)
Current draw
Alarm Memory
See Section6-4
Initial Alarm Memory
See Section6-4
Red and Yellow LED is blinking during warm-up period.
LED Indicator
Red LED-Alarm , Alarm Memory and Initial Alarm Memory indicator
Yellow LED-Anti Masking , Self-check indicator
D.L.terminal
See Section6-2
Trouble output
N.C. 28VDC 0.2A max.
Weight
4.8oz(135g)
2.76(70)
Dimensions : inches (mm)
PASSIVE INFRARED DETECTOR
CX-502, CX-502V, CX-502AM
STANDARD
ALARM MEMORY
ANTI-MASKING
FEATURES
CX-502
- Double Conductive Shielding of the pyroelectric element
- Extremely High Light and RFI Immunity (Patent listed)
- Multifocus Optics Design (Patent listed)
- LED On/Off Switch
- Super Quad Zone Logic
OPTION
- Temperature Compensation
LONG RANGE LENS : CL-80N
- Sealed Optics
- Silent Relay
FA-1W :
- LED Remote Control Terminal ((BE) model only)
FA-3
1.INSTALLATION HINTS
Avoid mounting detector where
Avoid direct unlight.
movement of Fans or Air
Conditioning Fans can be
detected.
‡ E
‡F
When damage has occured to the
product, i.e. water logged, abnormal
WARNING
things inside product, overheating
Never repair or modify
or smoking, strange smells etc., immediately stop using
product. It may cause
product and contact your supplier. Otherwise, continued
accident, fire hazard or
use in such condition may cause electric shock or fire
electric shock.
hazard.
2.DETECTION AREA
WIDE ANGLE
TOP VIEW
SIDE VIEW
3.DESCRIPTION AND OPERATION
Cover
Anti-masking prism
(CX-502AM only)
Do not touch.
Sensor
(Double Conductive Shield)
Lens
LED Indicator
Do not touch.
Sensitivity Selector
Cover Fastening
(See section 6-1)
S c r e w
Base
CX-502 V Only
CX-502 AM Only
- Alarm Memory
- Advanced Anti-Masking Technology
- LED Remote Control Terminal
- Self-check
- Alarm Memory and Initial Alarm Memory
- LED Remote Control Terminal
- 2 LED Indication
Wall Mount Bracket : adjustable ±45° (Horizontally), 0-20° (Vertically downwards)
:
Compact Wall & Ceiling Bracket : adjustable ±45° (Horizontally), 0-10° (Vertically downwards)
Avoid vapor or high humidity
Avoid Curtain,Screen,etc.
Do not install outdoors.
that can cause condensation.
blocking detection area.
‡ G
WARNING
CAUTION
Mount securely.
A falling product
may cause injury.
LONG RANGE
IMPORTANT
When using the optional "Long" range lens, ensure that the
detection mode switch is set to the "STD" position.
Ensure that the SENS Switch is set to the "H" position when
the detector is to be used in ranges longer than 67ft(20m).
TOP VIEW
SIDE VIEW
Wiring Knockout
Terminals
Corner mount Knockout
Mounting Knockout
Pitch 2.99inch(76mm)
Tamper switch
No.0881

Advertisement

loading

Summary of Contents for Optex CX-502

  • Page 1 7.TROUBLE SHOOTING No.0881 PASSIVE INFRARED DETECTOR PROBLEM PROBABLE CAUSE REMEDY CX-502, CX-502V, CX-502AM Improper power supply voltage. Correct supply voltage to 9~18V DC. (disconnection,low voltage) STANDARD ALARM MEMORY ANTI-MASKING RED LED does not light. Improper detection area. [See Section 2~4].
  • Page 2 (CX-502(BE) / CX-502V / CX-502AM only) point). 3) When the LED’s stop blinking the detector is set and ready for use. CX-502 The Alarm LED indicator can be switched either “ON” or “OFF” LED can be enabled or disabled remotely from Anti-Masking Blinks slowly (0.5sec)

This manual is also suitable for:

Cx-502amCx-502v