Download Print this page
Optex CX-702 MKII Installation Instructions

Optex CX-702 MKII Installation Instructions

Passive infrared detector

Advertisement

Quick Links

8
TROUBLE SHOOTING
PROBLEM
PROBABLE CAUSE
Incorrect power supply voltage. (disconnection, or low voltage)
LED does not light.
Improper detection area.
LED switch is OFF.
Improper polarity to detector.
LED lights even
Moving object within area. (curtain,wall hanging, etc.)
though no person
within area.
Temperature of object within area changing rapidly.
(heater, air conditioning, etc.)
LED lights but
Relay contact is stuck of damaged due to overloading.
signal is not sent.
Faulty Wiring.
LED continues to light.
Poor connection of alarm memory.
9
SPECIFICATIONS
Model
CX-702 MKII
Detection method
Passive infrared
Wide angle 90° wide
Long range
Coverage
21 m × 21 m
45 m × 10 m
(70 ft. × 70 ft.)
(150 ft. × 30 ft.)
Detection zones
136 zones
44 zones
Mounting height
1.5 to 3.6 m (5 to 12 ft.)
1.6°C at 0.6 m / sec., 2.4 m mounting height
Sensitivity
(3°F at 2 ft. / sec., 8 ft. mounting height)
Detectable speed
0.3 to 1.5 m / sec. (1 to 5 ft. / sec.)
Power input
9.5 to 16 V DC
Current draw
17 mA (normal) / 19 mA (max.) at 12 V DC
Alarm period
Approx. 2.5 sec.
Alarm output
N.C. 28 V DC 0.2 A (max.)
N.C., Opens when cover removed
Tamper switch
28 V DC 0.1 A (max.)
Pulse count
Approx. 20 sec. 2 or 4
Warm up period
Approx. 1 min.
LED indicator
Alarm condition
RF interference
No alarm 10 V / m
Operating temperature
-20°C to +50°C (-4°F to +122°F)
Environment humidity
95 % (max.)
Weight
200 g (7.0 oz.)
* Specifications and design are subject to change without prior notice.
■ EU contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorised representative in Europe:
OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS
Marandaz House 1 Cordwallis Park, Clivemont Road, Maidenhead,
Berkshire, SL6 7BU U.K.
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
OPTEX INC. (U.S.)
OPTEX SECURITY SAS (France)
URL: http://www.optexamerica.com
URL: http://www.optex-security.com
OPTEX DO BRASIL LTDA. (Brazil)
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.net/br/es/sec
URL: http://www.optex.com.pl
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex-europe.com
URL: http://www.optex.net/in/en/sec
OPTEX TECHNOLOGIES B.V. (The Netherlands)
URL: http://www.optex.eu
REMEDY
Correct supply voltage to 9.5 to 16 V DC. See Section 5.
See Section 2.
Turn on the switch.
Switch positive and negative at terminal.
Remove the souces from the detection area.
Remove object from the detection area.
Check load of output. The unit needs repair or replacement.
Wire correctly.
Reconnect wire.
Dimensions
100 (3.94)
Note>>
• This unit is designed to detect movement of an intruder and activate an
alarm control panel.
• Being only a part of a complete system, we cannot accept responsibility
for any damages or other consequences resulting from an intrusion.
(CX-702MKII Wide angle only)
EN 50131-1 Grades and Environmental Class:
Security Grade 2 and Environmental Class II.
EN 50131-2-2
Tested and certified by Telefication.
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
Copyright (C) 2016 OPTEX CO.,LTD.
- 4 -
PASSIVE INFRARED DETECTOR
PASSIVE INFRARED DETECTOR
CX-702 MKII
CX-702 MKII
FEATURES
● Dual Purpose Lens:Selectable "WIDE ANGLE" and "LONG RANGE" detection patterns
● Double Conductive Shielding of the pyroelectric element Extremely High Light and RFI
Immunity (Patent listed)
● Multifocus Optics Design (Patent listed)
● LED On / Off Switch
● Sealed optics
● Easy Installation
1
INSTALLATION HINTS
1
Avoid direct sunlight.
5
6
Do not install outdoors.
2
DETECTION AREA
WIDE ANGLE
mm (inch)
TOP VIEW
0
10
20
30
40
50
30
20
10
0
10
20
30
ft.
0
5
10
15
SIDE VIEW
0
10
20
30
40
50
0
A
5
ft. 8
0
5
10
15
0
10
20
30
40
50
0
B
5
8
ft. 12
0
5
10
15
0
10
20
30
40
50
0
C
5
8
ft. 12
0
5
10
15
INSTALLATION INSTRUCTIONS
OPTION
CA-1W : Wall Mount Bracket : adjustable ±45° (Horizontally),
CA-2C : Ceiling Bracket : adjustable ±45° (Horizontally),
2
3
Avoid mounting detector where
movement of Fans or Air
Avoid vapor or high
Conditioning Fans can be
humidity that can
cause condensation.
detected.
7
WARNING
When damage has occured to
WARNING
the product, i.e. water logged,
Never repair or modify
abnormal things inside product,
product. It may cause
overheating or smoking, strange
accident, fire hazard or
smells etc., immediately stop
electric shock.
using product and contact your
supplier. Otherwise, continued
use in such condition may cause
electric shock or fire hazard.
LONG RANGE
TOP VIEW
60
70 ft.
0
10
20
30
40
50
60
70
80
10
20
15
10
5
5
0
5
10
15
0
ft. 20
0
5
10
15
20
SIDE VIEW
5
0
10
20
30
40
50
60
70
80
0
A
5
10 m
ft. 8
0
5
10
15
20
20
21 m
0
10
20
30
40
50
60
70
80
0
B
5
60
70 ft.
8
0
ft. 12
1.5
0
5
10
15
20
2.4 m
20
21 m
0
10
20
30
40
50
60
70
80
0
60
70 ft.
C
5
0
8
1.5
ft. 12
2.4
0
5
10
15
20
3.6 m
20 21 m
**ATTENTION**
The specified detection area can be achieved by mounting the unit at a height of 2.4 m (8 ft.).
60
70 ft.
0
Mounting at a lower or higher height may reduce the area of coverage
1.5
2.4
3.6 m
20
21 m
- 1 -
No.59-2575-0 1612-15
EN
0 to 20° (Vertically downwards)
0 to 20° (Vertically downwards)
4
Avoid Curtain,Screen,etc.
blocking detection area.
8
CAUTION
Mount securely.
A falling product
may cause injury.
This symbol indicates prohibition.
* not certified with EN 50131-2-2
90
100
110
120 130
140 150 ft.
6
4
2
0
2
4
6 m
25
30
35
40
45 m
90
100
110
120 130
140 150 ft.
0
1.5
2.4 m
25
30
35
40
45 m
90
100
110
120 130
140 150 ft.
0
1.5
2.4
3.6 m
25
30
35
40
45 m
90
100
110
120 130
140 150 ft.
0
1.5
2.4
3.6 m
25
30
35
40
45 m

Advertisement

loading

Summary of Contents for Optex CX-702 MKII

  • Page 1 12 45 m ft. 12 3.6 m URL: http://www.optexchina.com 20 21 m OPTEX (EUROPE) LTD. / EMEA HQ (U.K.) OPTEX PINNACLE INDIA, PVT., LTD. (India) **ATTENTION** URL: http://www.optex-europe.com URL: http://www.optex.net/in/en/sec OPTEX (Thailand) CO., LTD. (Thailand) The specified detection area can be achieved by mounting the unit at a height of 2.4 m (8 ft.).
  • Page 2 Base ADJUSTMENTS FOR REQUIRED AREA PATTERN The CX-702 MKII is designed to provide ideal detection areas for different patterns ranging from 12 m (40 ft.) to 21 m (70 ft.) Wide Angle, and INSTALLATION 24 m (80 ft.) to 45 m (150 ft.) Long Range. The following adjustments will provide ideal detection areas for each of these requirements.