Replacement Parts Information - Mendota AA-11-00392 Installation And Operating Instructions Manual

Timberfire direct vent gas fireplace heater
Table of Contents

Advertisement

6.7 REPLACEMENT PARTS INFORMATION

How to Access Components
The descriptions below show where the main fireplaces components are located and how to access them for service. The
descriptions show how to access the components after the fireplace has been installed.
Pilot: The pilot light is located on the right side the firebox to the right ends the burners.
Gas Valve: The main gas valve is located behind the lower grill and beneath the firebox.
Complete Valve Assembly: To make working on components easier, this fireplace has been designed with the valve, pilot,
shutter boxes, shutter cables and gas lines as part of one assembly that can be removed from the fireplace. To remove the
assembly first remove burners and burner airbox. After disconnecting the gas line and wires, below the firebox, remove hex nuts
that secure the valve mounting plate to firebox floor. Lift up and remove the entire assembly from the firebox.
Convection Blowers: The convection blowers are mounted on the firebox's rear wall. To access the convection blowers, remove
the Valve Assembly first.
General Replacement Parts List
PART NO
65-02-00103
DOOR GASKET, 100" REQUIRED
65-06-00336
HA-20-00348
DOOR FRAME ASSEMBLY, DXV42
35-01-00240
35-01-00239
35-01-00201
05-02-00313
HA-30-00470
85-03-01116
DESCRIPTION
GLASS, DXV42
COALS 12 OZ BAG
GLOWING INSWOOL
FIREBRICK KIT, DXV42
SIT VALVE NAT. GAS
PILOT ASSEMBLY, LPG
PART NO
05-04-00035
HA-20-00294
HA-30-00470
65-14-00030
65-14-00049
15-02-00120
15-02-00121
65-06-01049
65-06-00455
DXV42 TIMBERFIRE
DESCRIPTION
PILOT ASSEMBLY. NAT. GAS
LP KIT
PILOT ASSEMBLY LPG
ORIFICE (NAT. GAS) # 30
FRONT ORIFICE (NAT. GAS) # 49
R H BLOWER WITH MOTOR
L H BLOWER WITH MOTOR
BLACK PAINT - 12 OZ. SPRAY CAN
KEL-KEM GLASS CLEANER/POLISH
Page 75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv42

Table of Contents