Mendota AA-11-00392 Installation And Operating Instructions Manual page 18

Timberfire direct vent gas fireplace heater
Table of Contents

Advertisement

Fireplace Features
EXTERNAL DIMENSIONS: 40" Wide X 31-1/4" High X 15-3/4" Deep
MINIMUM FRAMING DIMENSIONS: 41" WIDE x 33" HIGH X 16" DEEP
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 32-7/8" X 16-11/16".
MANTEL ALLOWANCE: 8" Deep Mantel at 9" Above Top Convection Opening (38-1/4" up from base of Unit)
VENT SYSTEM ALLOWANCE: Top Vent Only. 9" Vertical Minimum with 6" max horizontal. 36 feet Vertical Maximum. 4" exhaust
and 6-5/8" combustion air intake coaxial vent pipe required. 12' maximum horizontal run allowed with 4' minimum vertical
starter section.
VENT DAMPER ADJUSTMENT AVAILABLE: There is one exhaust vent damper included in this unit and located in the top
convection chamber at the center.
CONTROLS: Thermocouple Safety System with Standing Pilot Thermopile power generator. Thermostat option available.
BLOWER SYSTEM: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
BURNER SYSTEM: Single Stainless-Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Burner air shutter.
LOG SET: 6-piece, Premium Definition Log Set with Extreme glow and realism.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5" WC Minimum inlet pressure required.
LPG INFORMATION: LP conversion kit #HA-20-00294 is required. 12" WC Minimum inlet pressure required. For the DXV42
Timberfire LPG application, the orifice is to be drill size #50. For higher altitude, adjustment to orifice size may be necessary.