Dimensions and Technical Details
DXV42 TIMBERFIRE Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface.
ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY PRESSURE:
LP GAS CONVERSION KIT: This Fireplace comes configured for use with Natural Gas. To convert the Fireplace for use with LP
Gas, install: LP GAS CONVERSION KIT # HA-20-00294.
GAS INPUT RATES
BTUH .......................... NAT. GAS
BTUH .......................... L.P. GAS
ORIFICE SIZES............
[0-2000ft (610 m)]:#30 NG [49 L.P.]
FLUE VENTING ............COAXIAL RIGID- 4" DIAMETER EXHAUST &6-5/8" DIAMETER AIR INLET AND APPROVED VENT CAPS
All UL Listed Coaxial Rigid 4"X6-5/8" Vent pipe components and vent caps are approved for use. Do not mix components of
different brands or series. Always use the same brand and series components throughout the entire vent system.
UNIT TO FLOOR
UNIT TO ENCLOSURE SIDEWALL
UNIT TO ENCLOSURE BACK WALL
UNIT BOTTOM TO ENCLOSURE CEILING 53-3/8 in. (136 cm)
UNIT BOTTOM TO ROOM CEILING
DISTANCE TO 8" MANTLE ABOVE TOP CONVECTION AIR DISCHARGE OPENING
WIDTH = 36-1/4" (920 mm)
NET WEIGHT................185 lbs. (Team Lift recommended)
BARRIER SCREEN: A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use. The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY: AGA certified, manual spark ignition system with thermocouple safety.
CERTIFIED TO: ANSI Z21.88 – 2017
This Mendota Gas Fireplace has been tested and certified by:
Intertek Testing Services, 8431 Murphy Drive, Middleton, WI 53562\
ICBO#AA647-4
85-03-01116
NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
High Fire
40,000
38,000
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
0in. (0mm)
GLASS FRAME EDGE TO ADJACENT SIDEWALL
½ in. (13mm)
½ in. (13mm)
72 in. (1829 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
HEIGHT = 31-7/16" (799 mm)
DXV42 TIMBERFIRE
Low Fire
27,000
22,000
VENT PIPE TOP TO COMBUSTIBLES
VENT PIPE SIDES TO COMBUSTIBLES
VENT PIPE BOTTOM TO COMBUSTIBLES 1 in. (25 mm)
9 in. (229 mm)
DEPTH = 15-1/8" (384 mm)
12in. (305 mm)
2 in. (51 mm)
1 in. (25 mm)