Lectrical Technical References - Mendota AA-11-00392 Installation And Operating Instructions Manual

Timberfire direct vent gas fireplace heater
Table of Contents

Advertisement

3.3
ELECTRICAL TECHNICAL REFERENCES
AC Power Requirements
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
For normal operation, this appliance requires 120 VAC, 2 Amp power or a 6V DC power source. The AC
power supply to this Fireplace must be hot at all times and shall not have a switch installed in it.
This appliance is equipped with an electrical junction
box on the left side.
Planning for AC Power Connection
On the left-side of this appliance, you will find an
electrical junction box with a strain relief clamp. To
connect AC power to this Fireplace, follow these steps:
1.
Remove the junction box cover plate (secured
with two screws), route the 3wire end of an
extension cord or house power wire cable
through the strain relief in the cover plate.
2.
Strip the ends of the house power wires and the
three color coded wires within the junction box.
Connect each color-coded wire to corresponding colored wires within the junction box. Use the supplied wire nuts to
connect each wire pair ends.
AC Power Connection
STEP 1
Figure 3-31 Wire Connections
85-03-01116
Figure 3-30 Electrical Junction Box
Note: When connecting two braided wires using wire nuts, strip both braided wire ends
at least ½" and twist the two bare ends together before using wire nuts. When
connecting a braided wire to a solid copper wire, strip the solid copper wire end ½" and
the braided wire end ¾". Twist the braided wire around the solid copper wire end before
applying the wire nut.
3. Place connected wire ends within junction box then close and secure the junction box
cover plate.
STEP 2
DXV42 TIMBERFIRE
STEP 3
Page 40