6.7 REPLACEMENT PARTS INFORMATION

How to Access Components
The descriptions below show where the main fireplaces components are located and how to access them for service. The
descriptions show how to access the components after the fireplace has been installed. All components are also accessible from
the outside of the unit before the fireplace is installed.
Pilot: The pilot is in the center of the firebox between the burners.
Gas Valve: The main gas valve is located on the left side of the firebox. An inspection panel is provided on the left firebox wall
that allows inspection of the gas valve, wiring, and gas inlet connections.
Complete Valve Assembly: To make working on components easier, this fireplace has been designed with the valve, pilot,
shutter boxes, shutter cables and gas lines as part of one assemble that can be removed from the fireplace. To remove the
assembly first remove the inspection panel. This will allow the main gas inlet and wires to the valve and pilot to be disconnected.
After disconnecting the gas line and wires remove the screws from the valve mounting plate (13 on the left side and two on the
floor of the firebox). Then remove the entire assembly from the firebox.
Ignition Control Module: The ignition control module is mounted on the left side, in a protruding box beyond the main gas valve
(when accessing from inside the firebox). It is secured to the outer wall of the box with two screws. Access to the ignition control
module is available through the inspection panel. First remove the inspection panel. Then locate the ignition control module.
Convection Blowers: The convection blowers are mounted on the left and right sides of firebox. To access the convection
blowers, remove the left and right firebox side blower access plates.
Accent Light: The accent light is mounted in the firebox top center area. The accent light wire harness is run from the light
housing to the left side and then down to the ignition control module.
Please contact your Mendota Dealer for parts availability and parts pricing.
General Replacement Parts List
Please contact your Mendota Dealer for parts availability and parts pricing.
ITEM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
85-03-01104
PART
QTY
NUMBER
1
05-02-00344
1
05-04-00065
1
05-02-00416
1
65-07-00744
1
65-14-00037
1
65-14-00052
1
05-02-00345
1
10-03-00128
1
15-02-00129
1
15-02-00130.
1
10-11-00025
1
10-11-00020
1
HA-77-00256
1
HA-78-00210
110"
65-02-00103
1
65-06-01184
FV41 DECOR
DESCRIPTION
Valve, 885 ProFlame (NG) SIT# 0.885.001
PILOT, 3-WAY HOOD
SIT ProFlame II Control Module, 0.584.665
Ball Valve
NG Orifice, #37
LPG Orifice, #52
Backup Battery Holder
Backup Power Harness
Blower, LH
Blower, RH
Accent Light Lens
G9 Xenon, 25W Light Bulb
Glass Latch Tool
Glass Frame Weldment (no glass)
Glass Gasket, Tadpole,3/8" Bulb, ¾" Tail
Door Glass, NeoCeram
Page 87