6-5. Updating Software

Obtain the latest software to be loaded
from MillerWelds.com.
Copy the desired software to an approved
USB flash drive (see Section 12-1).
1
Adjust Control/Select Button
With the machine turned off, insert the
flash drive into the USB receptacle on the
front of the machine. Turn the Engine Con-
trol switch to the Run or Run/Idle position.
.
Do not start the engine.
When the machine has powered up, if valid
files exist on the flash drive, the user is
prompted to confirm the start of the down-
load. The Voltmeter/Ammeter display
reads: AL? NO.
.
A complete Parts List is available at www.MillerWelds.com
Confirm by rotating the Adjust Control/Se-
lect button clockwise to select YES. Then
press the Select button.
.
After the update has started, do not
power down or remove the flash drive
until the update is complete.
During the download, the left meter display
indicates the active download with AL U,
AP U, AL C, and AP C. The right meter dis-
play indicates the percentage of the down-
load completed with a number from 0 to
100. Software updates may take several
minutes.
1
If a valid update file for the weld module is
detected, the meter display reads AL
STRT to instruct the user to start the en-
gine. Do not power down the unit. Turn the
engine control switch to start and release.
The unit will follow its normal starting pro-
cedure. When the engine is running, the
left meter display will read AP W for the
weld module application update.
When the update has completed success-
fully, the Voltmeter/Ammeter display
reads: AL OK.
Failures are indicated on the meter display.
Correction of failed updates depends on
what type of failure occurred.