19. Using the − and + buttons, adjust the display to match the measured value.
20. Wait a few seconds, then verify display and voltmeter reading are the same.
21. Press the TIG button to save the calibration setting.
22. Press ELECTRODE button to exit calibration mode or continue on to Amperage Calibration procedure.
Amperage Calibration Procedure:
1. When in calibration mode, connecting shorting cable/load bank across output studs, then press the STICK button.
2. Verify the display shows 50 (±5.0).
3. Verify the ammeter displays 50 (±5.0).
4. Using the − and + buttons, adjust the display to match the measured value.
5. Wait a few seconds, then verify display and ammeter reading are the same.
6. Press the STICK button to save the calibration setting.
7. Verify the display shows 350 (±5.0).
8. Verify the ammeter displays 350 (±5.0).
9. Using the − and + buttons, adjust the display to match the measured value.
10. Wait a few seconds, then verify display and ammeter reading are the same.
11. Press the STICK button to save the calibration setting.
12. Press ELECTRODE button to exit calibration mode.
Default Calibration Procedure:
S
Three levels of calibration default are provided as follows:
Default all
Default voltage calibration
S
Enter calibration mode using the method described above.
Default all
S
When in calibration mode, press and hold the STICK and TIG buttons at the same time until the display shows — — —
S
Default voltage calibration
When in calibration mode, enter the voltage calibration mode by pressing the TIG button. Then press and hold the STICK and TIG buttons at the
same time until the display shows — — —
Default amperage calibration
S
When in calibration mode, enter amperage calibration mode by pressing the STICK button. Then press and hold the STICK and TIG buttons at
the same time until the display shows — — —

7-8. Updating Software In Welding Power Source

OM-263 657 Page 36
Default amperage calibration
1
SD Card
Insert SD card into the SD card slot
on the front of the unit. Turn power
on or cycle power to the welding
power source. Unit automatically
updates.
The update may take 20 to 30 sec-
onds. The front panel display may
show dashes and/or H99.
Upon completion of the update, the
display shows Crd. Remove SD
card to resume normal operation.
Press and hold the Electrode and In
Use push buttons simultaneously
to verify unit has updated success-
fully with the correct system soft-
ware revision level.
1
266 872