5-8. Connecting Optional External Fuel Supply

1
2
.
Connect fuel supply line to barbed elbow on fuel pump.
OM-281710 Page 28
.
A complete Parts List is available at www.MillerWelds.com
.
Connect fuel return
line to check valve.
!
Route all hoses away from
hot, sharp or moving parts.
Check all connections and
hoses for damage, leaks, and
wear.
1
Check Valve
2
Electric Fuel Pump
The pump provides a 96 in. vertical
lift between the Empty level of the
fuel tank and the pump inlet.
If connecting to an external fuel
supply, follow all applicable fuel
hose regulations.
To connect to an external fuel sup-
ply, disconnect factory hoses from
electric fuel pump and return check
valve. Use a 5/16 in. (7.94 mm) fuel
hose for fuel supply and a 3/16 in.
(4.76 mm) fuel hose for fuel return.
Connect supply hose to electric fuel
pump and return hose to check
valve.
Connect hoses and secure with
hose clamps. Use grommets if rout-
ing hoses through sheet metal.
Plug fuel line from tank.
Connect return fuel line.
Tools Needed:
907760