SECTION 9 − OPERATING AUXILIARY EQUIPMENT

9-1. Generator Power Receptacles And Supplementary Protectors

3
5
4
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord. Do
not use GFCI receptacle to power
life support equipment.
!
Unplug power cord before attempt-
ing to service accessories or tools.
.
Generator power decreases as weld
current or air compressor output in-
creases.
.
A complete Parts List is available at www.MillerWelds.com
1
1
120/240 V AC Receptacle RC1
RC1 supplies 60 Hz single-phase power at
power speed. Maximum output is 6.5 kVA/
kW.
2
120 V 20 A AC Receptacles RC2
and RC3
3
Supplementary Protector CB2
4
Supplementary Protector CB3
CB2 protects RC2 and CB3 protects RC3
from overload. If a supplementary protector
opens, the receptacle does not work.
2
Ref. 281606-A
.
Press button to reset supplementary
protector. If supplementary protector
continues to open, contact Factory
Authorized Service Agent.
5
Supplementary Protector CB1
CB1 protects RC1 from overload. CB1
supplies power to RC2 and RC3.
Combined output of all receptacles limited
to 6.5 kVA/kW rating of the generator.
OM-281710 Page 43