8.Specifications
■ List of specifications
<Flow velocity measuring amplifier MFS02>
Number of measurement points
Sampling period
Sampling speed
Velocity measurement range
Operating ambient temperature
Operating ambient humidity
Power supply specifications
Weight
※1 The measurement range may vary slightly depending on the thickness (t) of the molded part.
<AC adapter>
External dimensions (Main unit)
Operating temperature range
Operating ambient humidity
Power supply specifications
Weight
<LAN Cable WCL0020>
Standard
Total length
Operating temperature range
<Relay amplifier>
Light source LED
Operating temperature range
Operating ambient humidity
Weight
2
1ms / 5ms / 10ms / 20ms
Up to 120 sec
10 to 1000 mm/sec
0 to +50℃
35 to 85%RH (no condensation)
Dedicated AC adapter should be used.
Input 12 VDC 0.5 A
Approx. 1,000 g
48.6(W)×63.5(D)×31(H)mm (See outline drawing)
0 to +40℃
20 to 80%RH (no condensation)
Input AC100V 50Hz/60Hz
Output DC12V 1.2A
Approx. 104 g
CAT 7
2 m
0 to +40℃
(Sold separately)
Red 4-element LED (waveform 630nm)
-20 to +55℃
35 to 85%RH (no condensation)
Approx. 75 g
1
31