Connecting The I/O Signals - FUTABA MFS02 Instruction Manual

Melt front speed measuring amplifier
Table of Contents

Advertisement

③ Connect the "GND" terminal to ground.
④ Connect the trigger signals from the injection molding machine.
⑤ Connect the LAN cable to the amplifier and PC.
Make sure that the connector is locked with a "click".
⑥ Connect the AC adapter.
2-5 Connecting I/O Signals
<<What is the input signal?>>
An input signal means a signal input to the amplifier from an external devices such as
a molding machine or ejector machine.
Trigger signal
Clear control signal
<<What is the output signal?>>
An output signal means a signal input from the amplifier to an external device such as
a molding machine or ejector robot.
Control Output signal
Required to start measurement. Upon the input of the trigger signal,
"measurement" is performed. Connect the "mold closing complete
signal".
Connected to clear (or cancel) the control signal being output from the
amplifier. Connect the signal as needed.
* The control signal can be cleared automatically by specifying the time in
the software settings (for details, see "Setting control outputs" on Page 17).
If automatic clear at the specified time causes no operational problem, the
connection of the clear control signal can be omitted.
A Control Output signal is output when the molten resin passes
through the sensor. This signal is used to control the injection
molding machine.