Sanyo VCC-HD5600P Series Manual page 135

Hide thumbs Also See for VCC-HD5600P Series:
Table of Contents

Advertisement

Upgrade has been terminated.
Upgrade has been interrupted due to power off, network fault, or other problem during the process.
Redo the upgrade by proceeding as follows.
1
Turn on the camera again.
2
Access the camera again.
3
Check the firmware version on [FIRMWARE UPDATE] in
* If the version number is updated: Upgrade is complete.
* If the version number is not updated: Redo the upgrade.
The date and time is not adjusted automatically by the NTP server.
1
Adjustment by NTP is not set as the method for automatic time adjustment.
CLOCK
Select
and set [CLOCK ADJUST] to [ON (NTP)].
2
The NTP server address is not configured correctly.
Select
CLOCK
and configure the [NTP SERVER ADDRESS] settings again.
3
The GATEWAY settings are not configured correctly.
NETWORK
Select
and configure the [GATEWAY] settings again.
The date and time information indicated on the live screen does not reflect the clock settings
configured on the [CLOCK SETTINGS] screen.
It is recommended that you delete temporary Internet files.
To do so, in Internet Explorer, click [Internet Options] in the [Tools] menu and then delete
temporary files, history, cookies, saved passwords, and web form information from the [General]
tab.
OPTION SETTINGS
screen.
Q&A 12/12