INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do
not install this heater as your primary heat source. If you have a central heating system, you may run system's circulating blower
while using heater. This will help circulate the heat throughout the house.
WARNING: A qualified technician must install heater. Follow all local codes.
WARNING: Never install the heater:
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top or sides of the heater.
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to
vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air exist, may cause walls discolored.
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining side and
back walls.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough
ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 8 through 10.
CHECK GAS TYPE
Use only the type of gas indicated on the plate. If your gas supply cannot meet that requirement, do not install heater.
CLEARANCES TO COMBUSTIBLES
Carefully follow the instructions below. This heater is a wall mount unit designed to sit directly on the floor or on a mantel base.
IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown
in Fig. 4. Measure from outermost point of heater.
Minimum Wall and Ceiling Clearances (see Fig. 4)
A. Clearances from outermost point of heater to any combustible
side wall should not be less than 12 inches.
B. Clearances from the heater to the ceiling should not be less
than 48 inches.
Fig. 4 - Minimum Clearance to Wall and Ceiling