Installation - Procom FBN400RHA Series Owner's Operation And Installation Manual

Table of Contents

Advertisement

NOTICE:
This heater is
intended for use as supplemen-
tal heat. Use this heater along
with your primary heating system.
Do not install this heater as
your primary heat source. If you
have a central heating system,
you may run system's circulat-
ing blower while using heater.
This will help circulate the heat
throughout the house.
WARNING: A qualified techni-
cian person must install heater. Fol-
low all local codes.
WARNING: Never install the
heater
l
in a bedroom or bathroom
l
in a recreational vehicle
l
where curtains, furniture, clothing,
or other flammable objects are
less than 42 inches from the
front, top, or sides of the heater
l
in high traffic areas
l
in windy or drafty areas
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to vinyl
or cloth wall coverings or operating
heater where impurities (such as
tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.
WARNING: Maintain the mini-
mum clearances. If you can,
vide greater clearances from floor,
ceiling, and adj oin ing
back walls.

INSTALLATION

Figure 4 -Minimum Clearance to Wall and Ceiling
IMPORTANT: Vent-free heaters add
moisture to the air. Although this is
beneficial, installing heater in rooms
without enough ventilation air may
cause mildew to form from too much
moisture. See Air for Combustion and
Ventilation, pages 5 through 6.
CHECK GAS TYPE
Use only the type of gas indicated on
the plate. If your gas supply can not
meet that requirement, do not install
heater. Call the dealer where you pur-
chased heater, for the proper type of
heater.
pro-
CLEARANCES TO COMBUSTIBLES
(Vent-Free Operation Only)
side and
Carefully follow the instructions below.
This fireplace is a freestanding unit
designed to set directly on the floor.
7
IMPORTANT: You must maintain
minimum wall and ceiling clearances
during installation. The minimum
clearances are shown in Figure 4.
Measure from outermost point of stove
top.
Minimum Wall and Ceiling Clearances
(see Figure 4)
A. Clearances from outermost point
B. Clearances from the stove top to
7
of stove top to any combustible side
wall should not be less than 12
inches.
the ceiling should not be less than
48 inches.