Start-up

12
12.1
Adjusting the door stop
36
The spring pre-tension is factory set to 210° and is normally not necessary to adjust.
If adjustment has to be carried out (see page 40).
1. Close the door.
2. Turn the potentiometer SPTE to 0° (if not already on 0°).
SPTE
3. Switch on the mains power (the operator will find its closed position).
0
0
4. Loosen the door stop arm.
5. Open the door to required open position, plus approx. 5/8" (15 mm), by turning
the potentiometer SPTE on the CU-ESD, clockwise.
SPTE
Issue 2007-10-11
CU-ESD
Start-up
≈ 95°
1003680-US-4.0